INSTALLATION AND OPERATING MANUAL Series GSO Richter Strainers Keep for future use! This operating manual must be strictly observed before transport, installation, operation and maintenance Subject to change without notice. Reproduction is generally permitted with indication of the source.
Series GSO Page 2 List of Contents List of Contents ......................................... 2 Relevant documents ................................. 2 Technical data ........................................... 3 1.1 Type plate, CE and body markings ............. 3 1.2 Tightening torques ....................................... 4 1.3 Pressure-temperature diagram.................... 4 2 Notes on safety .................................... 5 2.1 Intended use ................................................
Series GSO Page 3 Technical data Manufacturer : 1.1 Richter Chemie-Technik GmbH Otto-Schott-Str. 2 D-47906 Kempen Telephone:+49 (0) 2152 146-0 Fax: +49 (0) 2152 146-190 E-Mail : richter-info@idexcorp.com Internet: http://www.richter-ct.com The stainless steel name plate is undetachably riveted to the body.
Series GSO 1.2 Page 4 Tightening torques All screws greased, tighten opposite sequence! 1.3 in Pressure-temperature diagram diametrically The tightening torques for pipe screws and body screws mentioned must not be exceeded. For an exception, see Section 8, Flange connection valve / pipe is leaking. The following tightening torques are recommended. Pipe screws, flanges to ISO/DIN Flange nom.
Series GSO 2 Page 5 Notes on safety This operating manual contains fundamental information which is to be observed during installation, operation and maintenance. It must be read before installation and commissioning! Installation and operation are to be performed by qualified staff. For valves which are used in potentially explosive areas, see Section 3. The area of responsibility, authority and supervision of the staff must be regulated by the customer.
Series GSO 3 Page 6 Safety notes for applications in potentially explosive areas based on the Directive 94/9/ EC (Atex) The valves are intended for use in a potentially explosive area and are therefore subject to the conformity assessment procedure of the directive 94/9/EC (ATEX).
Series GSO 4 Safety note for valves, certified to Clean Air Act (TA-Luft) On request, this valve can be supplied compliant with the German Clean Air Code. Certificate / Manufacturer Declaration Validity is dependent on the operating instructions being read and observed. 5 Page 7 In particular, servicing must be conducted at regular intervals, and the bolted connections relevant for tightness must be inspected and retightened if necessary.
Series GSO 6 Page 8 Installation Examine valve for in-transit damage, damaged strainers must not be installed. Before installation the valve and the connecting pipe must be carefully cleaned to remove any dirt, especially hard foreign matter. During installation, pay attention to the correct tightening torque, aligned pipes and tension-free assembly. 6.1 Flange caps and gaskets Leave protective caps on the flanges until just prior to installation.
Series GSO 8 Page 9 Malfunctions Clogged strainer basket Remove and dismantle entire strainer basket, clean or replace and install again. See Section 9.1 and 9.2. Strainer basket sticks If functional parts swell owing to the medium, it is very difficult to remove the strainer basket. If dismantling is not possible by pulling the unit upwards, remove cover 106 and push the strainer basket upwards from below. 9 Dismantling by pushing downwards is not possible owing to the anti-torsion insert 219.
Series GSO 10 Page 10 Drawing 10.1 Legend 100 106 107 109 115 216 217 219 * body cover upper cover transition cover cover disc filter web * strainer basket support anti-torsion insert Mesh: 85, 105, 250, 500, 1000, 1500 1800, 2000 µm 10.2 Option Draining 9540-061-en TM 8361 Revision 10 Edition 10/2011 220 strainer basket compl.
Series GSO 10.
Series GSO Page 12 10.4 Dimensional drawing DN 25 40 50 80 100 L 160 200 230 310 350 H 165 205 213 314 324 H1 106 120 126 151 162 A 270 320 340 460 500 dimensions in mm ** DN 15 as standard, other DN on request Flange connecting dimensions: Flanges to DIN EN 1092-2, type B (ISO 7005-2, type B) PN 16 or flanges drilled to ASME B16.
Richter Chemie-Technik GmbH Otto-Schott-Straße 2 D-47906 Kempen www.richter-ct.
Safety Information / Declaration of No Objection Concerning the Contamination of Richter-Pumps, -Valves and Components 1 SCOPE AND PURPOSE Each entrepreneur (operator) carries the responsibility for the health and safety of his employees. This extends also to the personnel, who implements repairs with the operator or with the contractor. Enclosed declaration is for the information of the contractor concerning the possible contamination of the pumps, valves and component sent in for repair.
Declaration about the Contamination of Richter Pumps, -Valves and Components The repair and/or maintenance of pumps, valves and components can only be implemented if a completely filled out declaration is available. If this is not the case, delay of the work will occur. If this declaration is not attached to the devices, which have to be repaired, the transmission can be rejected. Every aggregate has to have it’s own declaration.
FAX Fax No. () Pages (incl. cover sheet) () To: () Contact person: () Your order No.: Our Kom. No.: Reference: () () () Extension: - () E-Mail Address: () Date: () Serial No.: () Dear Sirs, The compliance with laws for the industrial safety obligates all commercial enterprises to protect their employees and/or humans and environment against harmful effects while handling dangerous materials.