Technical Specifications
Essential
Essential Atmospheric gas water heaters for Manufactured
Housing feature the ammable vapor detection system
RichmondWaterHeaters.com
RICHMOND
®
WATER HEATERS
In keeping with its policy of continuous progress and product improvement, Richmond reserves the right to make changes without notice.
Richmond Water Heaters • 1115 Northmeadow Parkway, Suite 100, Roswell, Georgia 30076
© Rheem Manufacturing Company •
01/18
•
FORM NO. T-635 Rev. 4
EFFICIENCY
• .59 - .60 UEF
PERFORMANCE
• FHR: 57 gallons for 40-gallon model and
52 gallons for 29-gallon model
• Recovery: 30.3 to 34.3 GPH at a 90° F
rise, depending on model
LONGER LIFE
• Premium grade anode rod provides
long-lasting tank protection
FLAMMABLE VAPOR
DETECTION SYSTEM
• Exclusive air/fuel shut-off device for
double protection
• Maintenance free – no lter to clean
• Disables the heater in the presence of
ammable vapor accumulation
FLEXIBILITY
• Field convertible controls and burner
assembly for natural gas or LP operation
included
ALTITUDE CERTIFICATION
• All models certied up to 8,400 feet
above sea level
• High altitude model available for
29-gallon (4,500 to 10,000 ft.)
LOW EMISSIONS
• Eco-friendly burner, low NOx design
• Meets 40 ng/J NOx requirements
PLUS…
• Certied for manufactured (HUD) and
modular construction
• Side inlet temperature and pressure
relief valve opening
• Factory installed temperature and
pressure relief valve – side location
• Low lead compliant
• Two hole top for anode rod and hot
water outlet
• Specially formulated glass lining
prevents corrosion and extends the life
of the tank
• Piezo ignition – easy light pilot, no
matches required
• Cold water inlet – side connection
allows for quick, economical hook-up
• Optional leg kit for replacement units
• EverKleen
™
patented system ghts
sediment build-up
WARRANTY
• 6-Year limited tank and parts warranty*
* See Residential Warranty Certicate for complete
information
Units meet or exceed ANSI requirements and have
been tested according to D.O.E. procedures. Units
meet or exceed the energy efciency requirements of
NAECA, ASHRAE standard 90, ICC Code and all state
energy efciency performance criteria.
Essential
Atmospheric for
Manufactured Housing
29 and 40-Gallon Capacities
Up to 34,000 BTU/h
Natural and LP Gas
E
G
BA
C
F
HOT
WATER
CONNECTION
D
1/2"
3/4" N.P. T.
RELIEF
VALVE
OPENING
FLUE
3/4" N.P.T.
ANODE ROD
20-1/8"
COLD
WATER
CONN.
3/4"
N.P.T.
Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements.
* Adjustable length roof jacks
**Fixed length roof jacks
Roof jack must be ordered separately with 29 and 40-gallon atmospheric models
and must be in accordance with instructions furnished with the heater. Clamps
and secure strapping are packed in water heater carton.
DRAFT DIVERTER
Improved design
provides efcient
heating with down-draft
protection.
DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO.
T
Y
P
E
NOMINAL
GALLON
CAPACITY
RATED
GALLON
CAPACITY
MODEL
NUMBER
GAS INPUT
IN THOUS.
BTU/H
RECOVERY
IN G.P.H.
90° F RISE
FIRST HR.
DELIVERY
G.P.H.
H T. T O
VENT
A
TANK
HEIGHT
B
DIAM.
C
H T. T O
GAS
CONN.
D
VENT
SIZE
E
WATER
CONN.
CENTER
F
H T. T O
SIDE T&P
VALVE
G
SHIP
WEIGHT
(LBS)
UNIFORM
ENERGY
FACTOR
(UEF)
EST.
YEARLY
ENERGY
COSTN AT. LP N AT. LP
Tall 29 28 6V30FT3 32 30 32.3 30.3 52 59-5/8 56-7/8 16-1/2 14-3/8 3 or 4 8 50-7/8 110 0.60 $201
Tall 40 38 6V40FT3 34 32 34.3 32.3 57 61-1/2 58-1/2 18-1/2 14-3/8 3 or 4 8 52-1/4 125 0.59 $205
ROOF JACKS
PART NO.
ROOF OPENING
TO FLOOR DIM.
ROOF JACK
ADJ. RANGE
AP12118B* 98" Min./126" Max. 16" Min./32" Max.
AP12118C* 112" Min./154" Max. 30" Min./60" Max.
AP12118D* 130" Min./189" Max. 48" Min./95" Max.
AP12119B** 94" Min./106" Max. 12"