Technical Specifications
Essential Plus
Essential Plus Heavy Duty gas water heaters exceed
ANSI standards for ammable vapor ignition resistance
RichmondWaterHeaters.com
RICHMOND
®
WATER HEATERS
In keeping with its policy of continuous progress and product improvement, Richmond reserves the right to make changes without notice.
Richmond Water Heaters • 1115 Northmeadow Parkway, Suite 100, Roswell, Georgia 30076
© Rheem Manufacturing Company •
01/18
•
FORM NO. T-646 Rev. 4
Essential Plus
Heavy Duty
75 and 98-Gallon Capacities
75,100 BTU/h
Natural and LP Gas
EFFICIENCY
• Recovery Capacity: 72.8 gallons per
hour (delivers approximately 100 gallons
of hot water in the rst hour for
75-gallon models and 142 gallons for
98-gallon models)**
FLAMMABLE VAPOR
DETECTION SYSTEM
• Exclusive air/fuel shut-off device for
double protection
• Maintenance free – no lter to clean
• Disables the heater in the presence of
ammable vapor accumulation
EASY TO LIGHT
• Piezo Ignitor – no matches required
LOW EMISSIONS
• Eco-friendly burner, low NOx design
• Meets 40 ng/J NOx requirements
LONGER LIFE
• Premium grade anode rod provides
long-lasting tank protection
HIGH ALTITUDE COMPLIANT
• All models are certied for applications
up to 8,500 feet above sea level
PLUS…
• Temperature and pressure relief valve
included
• Low lead compliant
• Side water connections for space
heating applications
• Standard replacement parts
WARRANTY
• 6-Year limited tank and parts warranty*
* See Warranty Certicate for complete information
Efciency | All models tested according to ANSI
test procedures, and meet or exceed the thermal
efciency and standby loss requirements of current
ASHRAE standard (EPact). Also exceeds energy
efciency codes of all states including California
Energy Commission (CEC).
Safety and Construction | Design certied by CSA:
For operation at 160 degrees; meets all safety and
construction requirements of ANSI Z21.10.3; as an
automatic storage or instantaneous water heater;
as an automatic circulating tank water heater; and
for operation on combustible oors and in alcove
installations. All models are North Carolina Code
compliant. Certied for 150 PSI maximum working
pressure.
Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements.
**Recovery Capacity is based upon a 100° F water temperature rise and calculated per ANSI Z21.10.3 standards.
• 160° F Max. temperature setting.
E
G
BA
C
F
H
HOT
WATER
CONNECTION
H
COLD
WATER
CONNECTION
D
1/2"
3/4" N.P.T.
RELIEF
VALVE
OPENING
FLUE
ANODE ROD
SIDE TAPS
DESCRIPTION FEATURES ENERGY INFO.
T
Y
P
E
NOMINAL
GALLON
CAPACITY
RATED
GALLON
CAPACITY
MODEL
NUMBER
GAS INPUT
IN THOUS.
BTU/H
RECOVERY
IN G.P.H.
100° F RISE**
FIRST HR.
DELIVERY
G.P.H.
H T. T O
VENT
A
TANK
HEIGHT
B
DIAM.
C
H T. T O
GAS
CONN.
D
VENT
SIZE
E
WATER
CONN.
CENTER
F
H T. T O
SIDE T&P
VALVE
G
WATER
CONN.
SIZE
H
SHIP
WEIGHT
(LBS)
UNIFORM
ENERGY
FACTOR
(UEF)N AT. LP NAT. LP
Tall 75 73 6G75-76F 75.1 – 72.8 – 100 64 60 26-1/4 14-3/4 4 11 53-1/4 1 320 0.61
Tall 75 73 6G75-76PF – 75.1 – 72.8 100 64 60 26-1/4 14-3/4 4 11 53-1/4 1 320 0.61
Tall 98 93 5V100F-76N 75.1 – 72.8 – 142 67-7/8 64 28-1/4 14-7/8 4 11 57-3/16 1 350 0.58
Tall 98 93 5V100F-76P – 75.1 – 72.8 142 67-7/8 64 28-1/4 14-7/8 4 11 57-3/16 1 350 0.58