Use And Care Manual
15
For increased energy efficiency, some
water heaters have been supplied with
two 24” sections of pipe insulation.
Please install the insulation, according to
the illustrations above, that best meets your
requirements.
DO
❑ DO check inlet gas pressure to ensure that
it is within the range specified on the rating
plate.
❑ DO provide adequate air for combustion
and ventilation as discussed in the Use and
Care Manual and the National Fuel Gas
Code.
❑ DO maintain proper clearances to
combustibles as specified on the rating plate.
❑ DO ensure that the venting system
complies with the guidelines found in the
Use and Care Manual and National Fuel Gas
Code.
❑ DO contact a qualified service technician
if the pilot or main burner will not stay lit.
The burner chamber is designed to be sealed
utilizing a gasket and tamper resistant screws.
❑ DO ensure that the flue damper is not
obstructed and is free of debris.
DON’T
❑ DON’T block or restrict Combustion Air
Inlet Openings located around the lower
portion of the water heater jacket.
❑ DON’T remove the Burner Access Door
unless absolutely necessary. This should only
be done by a qualified service technician.
A new burner access door gasket must be
installed on any burner access door that has
been removed.
❑ DON’T install this water heater where
standing water may occur. The base of the
water heater is meant to be mounted on a dry
surface.
❑ DON’T operate the water heater if the
sight glass or burner access door grommet is
damaged or broken.
❑ DON'T manually open or close the
damper.
Typical vertical piping arrangement
Typical horizontal piping arrangement
During Installation of this water heater...........
Hot and Cold Pipe Insulation Installation
Installing the water heater
Burner Access
Door Grommet
Sight Glass
Flammable
Vapor Sensor
For increased energy efficiency, this water heater has been supplied with a 2 3/8”
section of T&P insulation. Please install the insulation as shown below.
T&P Insulation Installation
Typical Side Connect T & P Arrangement.
Typical Top Connect T & P Arrangement.
Slip the insulation cover over the T&P
Valve through the center hole and align
the hole in the side with the opening of the
T&P Valve.
Ensure the T&P Valve opening is not
obstructed by the insulation.