Use And Care Manual

15
A. Water Heater Location
Close to area of heated water demand.
Indoors and protected from moisture,
wet conditions, freezing temperatures
(below 32°F) and High temperatures
(above 140°F).
Area free of flammable vapours.
Provisions for Air Cirulation (Louvered
doors on ducting).
Provisions made to protect area from
water damage.
Sufficient room to service heater.
Six inches (6") of clearance from ceiling
to top of Hybrid Water Heater to allow
for filter maintenance.
Access to condensate disposal.
Vibration Isolation Kit (Non-Concrete
floors).
Hybrid seismic Kit (if required)
B. Water Supply
F. Ducting
Water heater completely filled with
water.
Air purged from water heater and piping.
Water connections tight and free of
leaks.
Flexible water connections.
HVAC approved ducting.
Calculated length of duct no greater than
maximum allowed.
UL Certified terminations (For ducting
to the outside).
Insulated duct.
Ducting adequately supported.
Ducting adequately isolated from structure.
C. Relief Valve
Temperature and Pressure Relief Valve
properly installed and discharge line run
to open drain.
Discharge line protected from freezing.
D. Wiring
Power Supply voltage agrees with water
heater rating plate.
Branch circuit wire and fusing or circuit
breaker of proper size. (Recommended
30 amp breaker)
Electrical connections tight and unit
properly grounded.
10 gauge wire.
E. Condensate Lines
Condensate lines from heat pump
installed correctly.
Condensate lines from heat pump run to
a suitable drain location.