Use And Care Manual

21
The Service screen provides information on the product description, testing
software version, and alarms. Alarm details can be found in the “Troubleshooting
Alarm Codes” section of the manual.
In case there is an active alarm, the “alarms” button will blink in the lower right
corner. Pressing the “Alarms” button will show a new screen containing the active
alarms and alarm history.
Pressing the "wi status" button will
show a screen with the Wi-Fi connection
status. An EcoNet App is available for
control of the heater remotely.
(Some models only).
Pressing the "sensors" button will show a
screen containing the temperature
readings of the tank and Heat Pump
System.
service
Tech Service Phone #: 800-995-0982
Product Model Number:
Product Serial Number:
Software Version Number:
WH-HPW4-H2-00-81
Water Heater Test Off
alarms
status
sensorswifi status
Water Heater Mode Off: ECO Trip
Electric Heat Control Off
Compressor Relay Off
Evaporator Fan Control Off
EXV Current Position 100.0%
The Status screen provides information on the current operating status, diagnostics,
and sensors.
Service
Status
Energy Saver Mode
StatusSettings
warm hot very hot
Mode
120°
Service
Energy Saver Mode
StatusSettings
warm hot very hot
Service Mode
120°
sensors
Upper Tank Temperature 73.6˚
Lower Tank Temperature 72.3˚
Ambient Temperature 74.9˚
Suction Temperature 74.9˚
Evaporator Temperature 75.4˚
Discharge Temperature 75.3˚
wifi status
wifi reset
Econet wifi sw version . . . . . . . . . RH-WIFI-02-00-66
Wifi module sw version . . . . . . . . AW300
Network MAC Address . . . . . . . . . 28-C2-DD-FF-8E-CB
Wifi Device status . . . . . . . . . . . . . . Wifi Setup
Wifi Signal strength [dBm] . . . . . . -256