E.5 Function selection setting
【1】Press ”FUNC” key and hold for 2sec, Multi-Display will shows the current setting
【2】Press ”UP”,”DOWN” key to choice the function (Fnc0,Fnc1,Fnc2,Fnc3)
【3】Press ”DSPL” key for Multi-Display back to monitoring battery voltage or 20sec without
press any key for automatically back to normal
E.6 Aux.1/2 Contact function selection setting
E.6.1 Aux.1/2 Contact Auto/ Manual ON,OFF operating instruction
【1】Press ”AUX1” key after, Multi-Display will shows the current status of AUX.1 or AUX.2,
“1Aon” – AUX.1 Current function in Auto mode, connection point close
“1AoF” – AUX.1 Current function in Auto mode, connection point open
“1Hon” – AUX.1 Current function in Manual mode, connection point close
“1HoF” – AUX.1 Current function in Manual mode, connection point open
“2Aon” – AUX.2 Current function in Auto mode, connection point close
“2AoF” – AUX.2 Current function in Auto mode, connection point open
“2Hon” – AUX.2 Current function in Manual mode, connection point close
“2HoF” – AUX.2 Current function in Manual mode, connection point open
【2】Press ”UP”,”DOWN” key to choice AUX.1 or AUX.2
【3】Press ”AUX1” key to choice connection point to be open or close
【4】Press ”DSPL” key Multi-Display back to monitoring battery voltage , or without press
any key for 20secto be automatically back to normal
E.6.2 Aux.1/2 connect point action operating instruction
Invertek 3 in 1 combined can planning connect point action are conditions as below:
1. Battery status 25%,50%,75%,100%
2. In Equalize Cycle
3. SOLAR CHARGER in action
4. CHARGER in action
5. AC IN action
6. BYPASS action
7. AC OUT action
8. INVERTER action
9. Over Temperature
10. Over Load
11. Battery Low/High
12. STOP
Operating instruction
【1】 Press ”AUX” Key and hold for about 2sec, Multi-Display will display the
current status of AUX. Contact “ry-1” it means AUX1; “ry-2” it means AUX2
【2】 Press ”UP”,”DOWN” to choice the AUX you have planned.
【3】 Press ”ENTER” Key after the Multi-Display will shows the current status of
what you have been planned connect point action condition detail. at
meantime when LED flash, it means the condition has settled
【4】 Press ”UP”,”DOWN” key to choice above condition for your planning
【5】 Press ”AUX” key to decide whether the condition has settled (Multi-Display
shows 0:Relieve ,1: Set up)
【6】 Press ”DSPL” Key Multi-Display will back to monitoring battery voltage, or
without press any key for 20secto be automatically back to normal
-17-