User manual

WLS-C Wheel Loader Scale - Operation 31
3. To shift the asterisk on the next value to be modified by pressing the Tare/Sel button..
4. Increase or decrease the value by pressing and releasing the Partial/Minus or Total/Plus button..
5. Press and release the Print/Enter button to save the changes. The asterisk will disappear.
6. Scroll to another page of the menu or return to the operation menu by pressing and holding the Tare/Sel
button to the previous menu.
4.13 User Menu
Use the following procedure to gain access to the User menu.
1. Press and hold the Print/Enter button for 3 seconds.
2. Scroll through using the Partial/Minus or Tare/Plus buttons.
3. Press and release the Print/Enter button to modify the sub-menu selected.
The following pages will show some tables describing all the existing menus in the system where:
The first column refers to the line of the display in which the text is written.
The second column describes the text shown on the display.
The third column describes the type of function implied, such as:
There are multiple functions accessible under the User menu.
*
Max Load 0.06
*
Max Load 0.00
Heading Refers to the menu’s title.
Visualize To view a set or memorized value.
Settings Refers to any value that can be modified.
Command Enables a function by pressing a command key.
Sub-menu Access Allows access to a sub-menu by pressing a command key.
Table 4-1. Definition of Types in Menu Tables
Menu
Line
Menu Text Typ e Description
1User Menu Heading
2 Tare: x.xx Visualize Last Tare value.
2 Weighing: On/Off Command Weighing enabled (On) or disabled (Off)
2 Max Load: xxx.xx Settings Current maximum load for warning lights function.
2 Machine: x Command To activate calibration 1 or 2 during operation mode.
Not available if regenerative valve present.
Table 4-2. User Settings Menu