User manual

22 WLS-C Wheel Loader Scale
3.9 Password (PIN) Menu
There are multiple functions accessible under the Password (PIN) menu.
3.10 Machine Setting Menu
There are multiple functions accessible under the Machine Setting menu.
Menu
Line
Menu Text Typ e Description
1
2 CAL. PIN XXXX Setting Insert the PIN to gain access to the calibration menu.
See “Setting New Values” on page 21.
2 Enter to Confirm Command Press Enter to confirm the PIN setting.
2 Access Denied Viewing This message is displayed if the PIN is incorrect.
Table 3-6. Password Settings Menu
Menu
Line
Menu Text Typ e Description
1 Machine Setting Text
2 Cylinder 1 xxxx Setting Setting lifting cylinder’s circumference for calibration
1, set in cm.
2 Rod 1 xxx Setting Setting cylinder rod’s circumference for calibration 1,
set in cm.
2 Thickness1 xxxx Setting Setting lifting cylinder’s thickness for calibration 1, set
in cm.
2 Cylinder 2 xxxx Setting Setting lifting cylinder’s circumference for calibration
2, set in cm.
2 Rod 2 xxxx Setting Setting cylinder rod’s circumference for calibration 2,
set in cm.
2 Thickness2 xxxx Setting Setting lifting cylinder’s thickness for calibration 2, set
in cm.
2 Round Val. xxxx Setting Setting rounding off value of partial weight. Default = 0
2 Active Angle x Setting Setting number for active angle sensor, range 0-1.
0 = Proximity Switch
1 = Angle Sensor (Default)
2 n.Decimals Setting Setting number of decimals for both partial and total
weight, range 0-3. Default = 2
2 Unit Print Command Selecting units of measure (0-none, 1-Kg, 2-Tons,
3-Lb., 4-Short Tons, 5-Cubic Meters) which will be
printed on the ticket.
NOTE: Only available if a printer is installed.
2 Del Ticket Num. Command Zeroing the progressive number on the ticket.
2 Use Reg. x Setting Enable or disable the regenerative valve management.
Table 3-7. Machine Settings Menu