User manual
WLS-C Wheel Loader Scale - Calibration 21
3.7.1 Setting New Values
Setting a new value, for example setting the Machine Setting, is completed using the following procedure.
1. Press and release the Print/Enter button. An asterisk will appear on line 1 above the value to be modified.
2. Modify the value of each figure by pressing and releasing the Partial/Minus button to change the value.
3. To shift the asterisk on the next value to be modified by pressing the Tare/Sel button.
4. Increase or decrease the value by pressing and releasing the Partial/Minus or Total/Plus button.
5. Press and release the Print/Enter button to save the changes. The asterisk will disappear.
6. Scroll to another page of the menu or return to the operation menu by pressing and holding the Tare/Sel
button to the previous menu.
3.8 Calibration Menu
There are multiple functions accessible under the Calibration menu.
Machine Setting
Rod 1
*
Rod 1 0
*
Rod 1 1
*
Rod 1 1
*
Rod 1 61
Menu
Line
Menu Text Typ e Description
1 Setting Menu Text
2 Machine Setting Access sub-menu Access Machine Setting menu. Use to set weighing
system main parameters.
2 Static Cal Access sub-menu Access to static calibration menu.
2 Dynamic Cal Access sub-menu Access to dynamic calibration menu, subdivided in
two sections; empty and loaded.
2 Angle Setting Access sub-menu Access to angles calibration menu.
2 Advanced Setting Access sub-menu Reserved for manufacturer’s settings.
Table 3-5. Calibration Settings Menu