User manual
WLS-C Wheel Loader Scale - Calibration 19
Figure 3-10. Empty Calibration Display
3.6 Loaded Calibration
Use the following procedure to perform a loaded calibration proceed as follows.
1. Access Loaded Cal. from the Dynamic Cal. menu.
2. Perform 10 lifts with a known load in the bucket at decreasing rpm settings, starting at the max RPM
with the bucket closed.
The Loaded Calibration menu includes the following data:
3 2 Back side cylinder pressure or differential pressure
43Time
5 3 Back side cylinder pressure or differential pressure
64Time
7 4 Back side cylinder pressure or differential pressure
XNTime
Y N Back side cylinder pressure or differential pressure
Setting Description
Time Time elapsed during the lift, obviously the lower this value, the greater the speed of the lift.
TP1 value Indicates the piston’s pressure transducer reading.
TP2 value Indicates the rod’s pressure transducer reading (if installed).
KnownLoad1 Set the known load for calibration 1: insert the value according to the machine’s capacity, keeping
in mind the decimals to be displayed, and the resolution preferred (this value can also be set at
the completion of the calibration).
LT1
1
point
Displays the number of lifts performed at decreasing speed, which will correspond to the number
of points recorded in loaded calibration 1 table, (refer LT1 xxxx: -xxxxx)
LT1 xxxx: -xxxxx Allows viewing the complete loaded calibration 1 table. It is possible to scroll through the table by
selecting the index number.
Table 3-4. Loaded Calibration Settings
Index Tabl e Description
Table 3-3. Index and Table Range