Specifications
60  RL-TA Series Operation Manual 
17.3.3  Numeric data 
6-digit numeric format: (D1-D7: seven characters) 
7-digit numeric format: (D1-D8: eight characters) 
D1 to D7(D8)  ASCII code  Description 
0 – 9  30H to 39H  Digits 0 – 9 
● 
2EH 
*  Decimal point (floating) 
*  Omitted when numeric data does not contain decimal 
places. In this case, space is output to the least 
significant digit. 
SP (Space)  20H 
*  A space heading a numeric value 
*  When numeric data does not contain decimal places, 
space rather than a decimal point is output to the least 
significant digit.
*1
*1 A numeric value is headed by 0 (30H) by factory default setting.  You can change the function setting 
so that it is headed by space (20H) rather than “0”. 
17.3.4  Unit (U1, U2: 2 characters) 
U1  U2  ASCII code  Unit  Balance indicators 
M  G  4DH  47H  milligram  mg 
(SP)  G  20H  47H  gram  g 
C  T  43H  54H  carat   
O  Z  4FH  5AH  ounce   
L  B  4CH  42H  pound   
O  T  4FH  54H  troy ounce   
D  W  44H  57H  pennyweight   
G  R  4BH  52H  Grain  GN 
T  L  54H  4CH  tael (Hong Kong)   
T  L  54H  4CH  tael (Singapore, Malaysia)   ►Top right 
T  L  54H  4CH  tael (Taiwan)    ► Bottom right 
M  O  4DH  4FH  momme  mom 
t  o  74H  6FH  tola   
P  C  50H  43H  parts counting  Pcs 
(SP)  %  20H  25H  percentage weighing  % 
(SP)  #  20H  23H 
Coefficient computation 
result 
# 