Specifications
    RL-TS Series Operation Manual  95 
Output  RS-232C compliant output is equipped as standard. 
D-SUB9P male (RS-232C output, port for external tare range setting, 
bi-directional) 
Span adjustment 
Span adjustment/test with external weights (Weights used are at least 50% of the 
weighing capacity) 
* Only the unit g can be used for span adjustment. 
Power  Dedicated AC Adapter: 6VDC/100 to 120VAC or 6VDC/230VAC  
Outside dimensions  310 mm (depth) × 208 mm (width) × 87 mm (height) 
Weight of the  
main unit 
TS-220 to TS-820:  Approximately 2 kg 
TS-2200 to TS-15K:  Approximately 2.5 kg 
Operating 
temperature/ 
humidity 
Temperature: 0 to +40°C, Humidity: 80%rh or less (No condensation allowed) 
Options  TS buzzer option/TS limit contact output option/TS full-pack option/TS RS422 
option (D-SUB9P)/External RS-USB converter/Direct start option/TS optional 
battery unit/TS underfloor weigher fixture option 
When using options, be careful of the following: 
- When using the RS422 option, D-
SUB9P is RS422 (Cannot be used 
together with RS232C). 
- Optional battery unit, limit contact output option, buzzer, and full-pack 
option cannot be used together. 
- 
The optional battery unit does not include batteries (use four AA 
batteries). 