Specifications

RL-TS Series Operation Manual 73
[S2] (one character)
Indicates the status.
S2 Code Description
S 53H Data stable *1
U 55H Data unstable *1
E 45H Data error *2 (Indicates that data other than S2 is invalid.)
(SP) 20H No status specified
*1: This value is independent of data if the data is independent of whether the weighing condition is
stable or not, such as cumulative values and unit weights.
*2: When “o --Err” or “u --Err” is displayed
Sample communication formats
- 6-digit numeric format
3000.1 g/No data type specified/Data stable
1 2 3 4 5 6 7 8 9 10 11 12 13 14
+ 0 3 0 0 0 . 1 (SP) G (SP) S CR LF
+800.05 mom/Gross/Data unstable
1 2 3 4 5 6 7 8 9 10 11 12 13 14
- 0 8 0 0 . 0 5 M O d U CR LF
250 pcs./Cumulative value/Data stable
1 2 3 4 5 6 7 8 9 10 11 12 13 14
+ 0 0 0 2 5 0 (SP) P C T S CR LF
- 7-digit numeric format
3000.1 g/No data type specified/Data stable
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
+ 0 0 3 0 0 0 . 1 (SP) G (SP) S CR LF
+800.05 mom/Gross/Data unstable
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
- 0 0 8 0 0 . 0 5 M O d U CR LF
250 pcs./Cumulative value/Data stable
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
+ 0 0 0 0 2 5 0 (SP) P C T S CR LF