Specifications
    RL-TS Series Operation Manual  29 
45BSetting a reference weight by entering a value 
1 
Set to the function setting mode. 
(Refer to “Section 2-5: Function Setting Basics 
(P. 
X22X).) 
Press and hold the [Function] key. After “Func” is 
displayed, release the finger. 
2 
Select “Percentage Weighing.” 
Press the [Zero/Tare] key several times to select “1.SEt 
3.” 
3 
Save the weighing mode. 
Press the [Target] key. 
The “percent weighing” mode is set, displaying “%.” 
4 
Start setting the reference weight. 
<Press and hold> 
Press and hold the [Function] key. After “P SEt” is 
displayed, release the finger. 
The previously-saved reference sample weight blinks. 
5 
Enter a reference weight. 
Set the reference value with the following steps: 
1. Press the [Zero/Tare] key. 
The digit furthest to the right side of the value 
blinks.. 
2. Select a number by pressing the [Zero/Tare] key. 
Pressing the key toggles the number between 0 and 
9, and decimal point. 
3. Pressing the [Function] key selects the number and 
the next digit blinks. 
Set the reference weight by repeating steps 2 and 3. 
Pressing the [Print] key can cancel the setting. 
6 
Save the value. 
Press the [Target] key to save the reference weight. 