Specifications

Configuration 23
Examples:
Scroll the message “Rice Lake Weighing Systems” 2 times
|00DM|0|N|N|Y|2|Rice Lake Weighing Systems!
Slide on and flash the message “DRIVE
AHEAD” for 5 seconds
|00DM|5000|Y|Y|N|0|DRIVE AHEAD!
3.7.3 Set or Get the Digital I/O
Notes:
Version 2.05 only accepts the serial digital I/O commands listed in this manual. All
previous serial digital I/O
commands prior to Version 2.05 will not work properly with this product.
The digital outputs are set to High (OFF) on reset.
To use the two Digital Inputs and
Digital Outputs, use J1 (See Figure 2-8 on page 8 ) to connect and use the
following message command
formats to set or get the Digital I/O
Set Relay (set relay output 1 off)
|00SR1OFF!
Response: OK = success (State: DO1_+5V) or ?? = error
Get Digital (input) 0
|00GRO!
Response: ON = gnd or OFF = +5V
Get Digital input levels (all digin)
|00DI!
Response: 0 = LL, 1 = LH 2 = HL, 3 = HH
Set Digital output levels to HH (all digout = +5V)
|00DO3!
Response: OK = success (states: DO0=DO1=+5V) or ?? = error
GB Get the number of 5 x 7 Max6953 boards (0 = 7-seg, 2, 3 = 5 x 7)
GV Get the version number
DC Dump configuration parameters (for
testing purposes only)
TP
Temperature adjustment. Allows +/- 5% degree adjustment
Time and date is sent from the remote display depending on the current remote display time and date format:
Time and date are sent to the remote display in ISO format.
USA Format: HH:MM:SS
AM/PM MMM/DD/YYYY
ISO Format: HH:MM:SS YYYY-MM-DD
If the real time clock is disabled in the remote display
, an error message is sent back.
Command Description