Specifications

Configuration 17
7-Segment
Display
Parameters
8-Character
Display
Parameters
12-Character
Display
Parameters
STOP STOPBITS STOP BITS 1
2
Selects the number of stop bits of Port 0
HOLD WT HOLD WT HOLD WEIGHT ON
OFF
Select On to enable this feature to keep the last
weight displayed if communication is l
ost or you are
using demand updated weight and prevents remote
display from going into an error condition.
LOCK LOCK LOCK ON
OFF
Select On to make sure the current settings don’t get
changed and to disable
Auto-Learn. When off, the
system enables the Auto-Learn function.
E CHAR END CHAR END CHAR CR
LR
FF
ETX
When Auto-Learn is enabled, this feature looks at the
la
st character to determine the end of a packet.
LW POS L WT POS LAST WT POS 5 - 50 Select a number between 5 and 50
to determine the
last weight position. If setting up Port 0 manually, the
last weight position is zero indexed. Example:
<STX>123456<CR> where <STX> is the start of the
text character, and <CR> is a carriage return
character, the “6” is in the 6th position, not the 7th.
LENGTH LENGTH LENGTH 5-75 Select a number between 5 and 75
to determine the
length of the packet in the string format.
Formats such as Toledo 8142 end in CR<AA> where
<AA> is
a 2-byte checksum, the checksum should
not be counted when calculating the format length.
PRIM U PRIM UNT PRIM UNITS A - Z Select a primary display character from A-Z. If
sel
ected, annunciator is lit
SECD U SECD UNT SECD UNITS A - Z Select a secondary display character from A-Z. If
sel
ected, annunciator is lit
GROS C GROSS CH GROSS CHAR A - Z Select a gross character charac
ter from A-Z. If
selected, annunciator is lit
NET C NET CHAR NET CHAR A - Z Select a net character character from A-Z. If selected,
an
nunciator is lit
MOTION MOTION MOTION A - Z Select a motion display character from A-Z. If
sel
ected, annunciator is lit
SP IND SP IND SPECIAL IND 1, 2, 3, 4 1 - Toledo 8142 format bit-mapped status da
ta
2 - Inclinometer custom program
3 - Flex-Weigh DWM IV
4 - Fairbanks 2500/and 9401 compatible units
5 - AnD 4323
0 - Off (Select when not using a special indicator)
Serial Menu
Table 3-5. Port 0 Serial Menu (Continued)