Specifications

16 LaserLight Remote Display Installation & Operation Manual
Serial Menu
Parameter Choices Description
Level 2 Submenus
Port 0 BAUD
PARITY
DATA BITS
STOP BITS
HOLD WT
LOCK
E CHAR
LW POS
LENGTH
PRIM U
SEC U
GROS C
NET C
MOTION
SP IND
Configure Port 0. See Level 3 s
ubmenu parameter descriptions.
Keeps last weight displayed if communication is lost a
nd prevents the remote
display from going into an error condition.
If enabled, prevents the Auto-Learn (Section 3.1) parameter from working
and ensures settings r
emain currently set.
This feature looks at the last character to determi
ne the end of a packet.
Can select a number between 5 and 50. Is zero indexed and determines last
weight position of the format.
Can select a number between 5 and 75 and determi
nes the length of packet
in the string format.
Select primary unit characters
Select secondary unit c
haracters
Select gross character
Select net character
Select motion status character
Select, decode status, and settings for specia
l indicator type.
0 = none
1 = Toledo 8142 format
PORT 1 BAUD
PARITY
DATA BITS
STOP BITS
ECHO
LOCK
Configure Port 1. See level 3 submenu parameter descr
iptions.
Disable this to allow echoing between r
emote display and other devices. Data
settings should be set equal to or greater than device being echoed to.
If disabled, remote display uses sam
e settings as indicator after an
Auto-Learn.
Table 3-4. Serial Communication Menu Summary
Serial Menu
Port 0
Parameter
Choices Description
Level 3 Submenus
7-Segment
Display
Parameters
8-Character
Display
Parameters
12-Character
Display
Parameters
BAUD BAUD BAUD 1200
2400
4800
9600
19200
Baud rate. Selects the transmission speed for Port 0
PARITY PARITY PARITY ODD
EVEN
NONE
Selects the parity of data of Port 0
DATA DATABITS DATA BITS 7
8
Selects the number of data bits of Port 0
Table 3-5. Port 0 Serial Menu
If selected, the
appropriate
annunciator is
lit