Installation manual
42 IQ9500 Installation Manual
Figure 9-4. Setpoint Mini DIN Female
Figure 9-5. Typical Wiring for 4 AC Outputs to Control Equipment in the Field
Pin Number Setpoint Configuration
1 SP-1
2 SP-2
3 SP-3
4 SP-4
5 SP-5
6 SP-6
7 +5 Vdc (external power
supply)
8 Gnd
Table 9-5. Pin Out for Setpoint Configuration
SPARE
FUSE
FUSE
TESTER
123456789
23456789
OPTO 22
G4PB4
FIELD CONTROL
OAC5 OUT
OAC5 OUT
OAC5 OUT
OAC5 OUT
FUSE-HIGH VOLTAGE
AC
IN
OUT
–
+
COM
HOT
GRD
AC WIRING TO CONTROLLED EQUIPMENT IN FIELD
DC CONTROL WIRING FROM IQ 9500
AC OUTPUT 4
TO EQUIPMENT
AC OUTPUT 1
TO EQUIPMENT
AC OUTPUT 2
TO EQUIPMENT
AC OUTPUT 3
TO EQUIPMENT
115 VAC
HOT IN
PIN 1 - SETPOINT 1
PIN 2 - SETPOINT 2
PIN 3 - SETPOINT 3
PIN 4 - SETPOINT 4
PIN 7 - 5 VDC
PIN 8 - GND
CAUTION:
HOT AND COMMON
SHOULD NOT BE
SWITCHED