Installation manual
36 IQ9500 Installation Manual
8.7 Data
Parts identification (ID) code is only sent when an ID
code is called during the counting mode. The
maximum is 16 characters. If the ID code is less than
16 characters, then the rest of the data will be filled
with space (20H). An example for parts code that
equals 12 is shown in the diagram below.
Setpoint data is only sent when an ID code is called
during the counting mode. There are six setpoint data
to be sent: Setpoint 1 (F or G), Setpoint 2 (H),
Setpoint 3 (a), Setpoint 4 (b), Setpoint 5 (c) and
Setpoint 6 (d).
Setpoint 1 (F) is defined as:
• Weight – variable length, maximum of five digits
and one decimal point.
Setpoint 1 (G) is defined as:
• Quantity – variable length with a maximum of six
digits.
NOTE: Only one F (Setpoint 1 – Weight) or one G
(Setpoint 1 – Quantity) is sent.
Setpoint 2 through 6 (H, a, b, c, and d) is data with a
format consisting of:
• Percentage – variable length, maximum of five
digits, and one decimal point, or
• Lower weight – variable length, maximum of five
digits, and one decimal point, or
• Lower quantity – variable length and a maximum
of seven digits.
Four combinations of Setpoint 1 and Setpoint 2 can be
sent as shown below:
Shown in Table 8-13 is the result of printed data
detailed above:
Table 8-13. Result of Printed Data
8.8 Status Data Byte
The status data byte for bits 0 through 7 is shown
below. Status data byte will be set either to 1 or 0 in
bits 0 through 5 or always set to 1 (bit 6) or 0 (bit 7).
Setpoint 1 Setpoints 2, 3, 4, 5, and 6
Quantity Percentage
Upper uantity Lower quantity
Weight Percentage
Upper weight Lower weight
NOTE: Setpoints 2 through 6 must either increase or
decrease. The decimal point for weight must be correct.
Header Data
31
SP
SP SP SP SP SP SP SP SP SP CR
2
Printed
Descriptor
Description
GROSS
WEIGHT
Variable length, maximum of five digits
and one decimal point
NET WEIGHT Variable length, maximum of five digits
and one decimal point
UNIT WEIGHT Variable length, maximum of five digits
and one decimal point
TARE WEIGHT Variable length, maximum of five digits
and one decimal point
QUANTITY Variable length, maximum of seven digits
TOTAL
QUANTITY
Variable length, maximum of seven digits
when PRINT key is depressed
NOTE: Only one of “2” (QUANTITY) or “1” (TOTAL
QUANTITY) is sent at one time.
Bit If Set to 1 If Set to 0
0 Positive weight Negative weight
1 Lb mode Kg, g mode
2 Weight stable Weight unstable
3 Output normally
entered data
Others
4 Output by + key Others
5 Output by – key Others
6 Always set to 1
7 Always set to 0