Installation manual
RS-232 Specification 35
There are two type of headers; header with header code and header with title. The header code is sent before the
data to indicate the type of the data, while the header with title is sent before the data to indicate the type of the
data. This can be used only when RS-232 output is set to counting condition, with header and title. Table 8-12
shows the type of data that can be sent.
8.6 IQ9500-to-PC Output Data Format
Without Header
The IQ9500-to-PC output data format (without
header) is identified in SPEC 12, bit 0 (
RS-232C (PC)
with Header) and is set to 1. The output data format is
data only. One data block consists of Data and CR.
The following is an illustration of the output data
format.
NOTES:
• CR must be added at the end of the data.
• LF must be added at the end as a termination code of
the transmission.
Header Code ASCII Code Data Title Data
0 30 Net Weight NET WEIGHT Net Weight
1 31 Unit Weight UNIT WEIGHT Unit Weight
2 32 Quantity QUANTITY Quantity
3 33 ID Code ID CODE ID Code
4 34 Tare Weight TARE WEIGHT Tare Weight
A 41 Gross Weight GROSS WEIGHT Gross Weight
B 42 Status STATUS Status
C 43 Date and Time DATE AND TIME Date and Time
F 46 Setpoint 1 (W) SETPOINT 1 (W) Setpoint 1 (W)
G 47 Setpoint 1 (Q) SETPOINT 1 (Q) Setpoint 1 (Q)
H 48 Setpoint 2 SETPOINT 2 Setpoint 2
I 49 Total Quantity TOTAL QUANTITY Total Quantity
K 4B Inventory INVENTORY Inventory
M 4D Part No PART NO Part No
N 4E Part Name PART NAME Part Name
V 56 Scale No SCALE NO Scale No
Q 51 Setpoint 3 SETPOINT 3 Setpoint 3
X 58 Setpoint 4 SETPOINT 4 Setpoint 4
U 55 Setpoint 5 SETPOINT 5 Setpoint 5
O 4F Setpoint 6 SETPOINT 6 Setpoint 6
Table 8-12. IQ9500 RS-232 Specification with Header
Data CR Data CR ........ CR LF