Installation manual
22 IQ9500 Installation Manual
23 0000 Display Resolution for Scales 1, 2, 3, and 4
00: 1/10,000 01: 1/5,000
10: 1/2500 11: Not used
Zero Setting Range
00: +Unlimited/–10% FS 01: ±2% FS
10: ±10% FS 11: Not available
24 0001 Masked Display at
Minus Weight
0: Gross
1: Net
Display at Minus
Weight
0: Minus display
1: Masked
Zero Lamp Lighting
Method
0: Gross
1: Net
Low Battery (turn off
display)
0: No
1: Yes
25 00_0 Scale Starting
Method
0: Automatic
1: Manual (must
press REZERO key)
IR Mode Protected by
Span Switch
0: No
1: Yes
Scale Type
0: Single scale
1: Dual scale
NOTE: If you are not
connected to a
dual-platform IQ9500,
or do not have two
scales wired into
Cable Port 1, then this
bit needs to be set to 0
(single scale).
Selecting 1 (dual
scale) can damage the
console’s electronic
components.
Gross Mode Available
0: Yes
1: No
26 0000 Zero Tracking When
Tare
0: Yes
1: No
Rezero with a Tare
Weight
0: Yes
1: No
Initial Start Range
00: +Unlimited/–10% FS 01: ±2% FS
10: ±10% FS 11: Not available
27 0100 Comma Display
0: No
1: Yes
Digital Tare Setting
0: No
1: Yes
Tare Range
00: 100% FS 01: 50% FS
10: 5% FS 11: Not available
28 0000 Auto Tare Clear
When Rezero
0: No
1: Yes
Automatic Unit Weight Clear Condition
00: Over net 5d and gross 21d and weight
stable
01: Greater than or equal to net 1d and weight
stable
10: Greater than or equal to net 1d and quantity
greater than zero and weight stable
Automatic Unit Weight
Clear
0: No
1: Yes
29 0000 Digital Tare
Rounding
0: Tare exactly
1: Round to nearest
increment
Tare Value Exchange
with TARE key
0: Yes
1: No
Tare Addition
0: Yes
1: No
Tare Subtraction
0: Yes
1: No
30 1001 Load Cell Sensitivities Selection (mV/V)—Scale 1
Auto
adjusting
Spec
Min Max
0000: 3.46 4.00
0001: 3.00 3.46
0010: 2.59 3.00
0011: 2.25 2.59
Spec
Min Max
0100: 1.95 2.25
0101: 1.69 1.95
0110: 1.46 1.69
0111: 1.27 1.46
Spec
Min Max
1000: 1.09 1.27
1001: 0.95 1.09
1010: 0.82 0.95
1011: 0.71 0.82
Spec
Min Max
1100: 0.61 0.71
1101: 0.53 0.91
1110: 0.46 0.53
1111: 0.40 0.46
31 1001 Load Cell Sensitivities Selection (mV/V)—Scale 2
Specification Default Bit 3 Bit 2 Bit 1 Bit 0
Table 5-2. Applicable IQ9500 Weight and Measurement Specifications (142 Settings) (Continued)