Installation manual

18 IQ9500 Installation Manual
5.0 Configuration/Dealer Settings
This section presents the setup and conguration of
the IQ9500 counting scale to be used specically by
distributors and service technicians. These
conguration settings will congure the counting
scale to specic bit settings that can be tailored to
individual applications.
Setting conguration allows you to easily modify the
functionality of your IQ9500. Use the tables in this
section to view the options you can modify. For
example, if you want the
Unit Weight Auto
Recomputing function to work on your IQ9500, you
refer to the IQ9500 specication table and locate
SPEC 5. Go across the row and see that bit 2 controls
this function. The default for SPEC 5 is 0011, which
means that the
Unit Weight Auto Recomputing
function is turned off. To turn it on, you would change
the bit string to 0111.
5.1 141 and 142 Settings
The following tables list the IQ9500 specications
and their corresponding default values. Each
specication (SPEC) consist of four bits (bits 0
through 3) and represent various settings or selections.
SPEC 1 through SPEC 19 (Table 5-1) are customer
specications and use the
141 access code while
SPEC 20 through SPEC 39 (Table 5-2) are weight and
measurement specications and use the
142 access
code.
5.1.1 Customer Specification (141 Settings)
1. Press and hold the REZERO key and enter
141 using the numeric keypad. SPC00
appears in the WEIGHT display and congura-
tion of four bits (for SPEC 0) appears in
QUANTITY display. Bit 3 is the left digit in
QUANTITY display.
2. Press the
+ key to move up through each
specication until the desired specication is
obtained. (Press the
key to move down
through each specication.)
3. Enter the new bit string (four bits required)
starting with bit 3 and then move either up or
down to store bit settings into temporary
memory.
4. Repeat Steps 2 and 3 until all specications
are changed.
5. Press
* key and then MODE.
6. Power down scale.
7. Power scale ON to re-initialize the new
specication settings.
Specication Default Bit 3 Bit 2 Bit 1 Bit 0
0 0000 Transfer Tare
Weight
0: No
1: Yes
Digital Tare
Accumulation
0: No
1: Yes
Terminator
(RS-232 only)
0: Carriage return
1: Carriage return
linefeed
Piece Weight
Selection
0: U.W. per/1000
1: Unit wt. per piece
(A.P. W.)
1 0000 Power Auto Off Function: The example below shows the binary code, the corresponding
time, and a binary code description. Settings can range from 0 to 15 minutes with 1 minute
increments (examples of 0-, 7-, and 15-minute settings are shown below).
Binary Code
8421
Time (min) Description
0000 0 Autopower off is disabled.
0111 7 If the net weight is zero and no motion for 7 minutes, the scale will go into
autopower off mode.
1111 15 If the net weight is zero and no motion for 15 minutes, the scale will go
into autopower off mode.
NOTE: Powering down means that accumulated value will be lost and not retained upon
power up. However, all total inventory values stored with item codes will be retained.
Table 5-1. Applicable IQ9500 Customer Specifications (141 Settings)