Users Manual
CS200, Users
August, 2009
3
Introduction
This manual contains specifications and operation instructions for Intercomp's model
CS200 Crane Scale.
Specifications
Controls
General: Zero, backlight, On/Off.
Display: 4 digit LCD.
Electrical
Batteries: 1 (9-volt) size disposable alkaline or rechargeable Nickel-
Cadmium cell.
Resolution: 14 bit A/D delivers over 16,000 internal counts..
Auto-Zero: Automatically zeros off errors of zero-load.
Battery life: 300 hours with an alkaline battery
20 hours with backlight on
Low battery indication:
Flashes “batt
battbatt
batt” when battery is running low; Turns off if
battery power is low enough to affect reliability.
Performance
Accuracy: ±0.1% of applied load or ± 1 display graduation, whichever is greater
Environmental
Humidity: 10 to 95% Non-Condensing.
Temperature:
Operating: -10 C to +50 C. / +15 F to +122 F.
Storage: -40 C to +75 C. / -40 F to +170 F
Physical
Dimensions:
Height: 3.3" (6.2" with hooks) / 8.4cm (15.7cm with hooks)
Width: 4.4" / 11.2cm
Depth: 2.5" / 6.4cm
Weight: 1.1 lbs / 0.5 kg to 1.5 lbs / 0.7 kg depending on capacity