Users Manual

CS200, Users
August, 2009
14
Error Messages
dISP
dISPdISP
dISP
Display error, the scale is unable to display the number completely. If no
weight on the scale, press zero to return the weight reading to zero.
EEPE
EEPEEEPE
EEPE
EEPROM error, the scale has had it's calibration corrupted or destroyed;
the scale will require calibration.
OE
OEOE
OE
The scale is over capacity or outside the A/D converter range. Reduce the
load to the scale. If the CS200 continues to display “OE
OEOE
OE”, the problem
could be a bad load cell, bad load cell wiring, or a bad chip on the circuit
board.
OvEr
OvErOvEr
OvEr
The CS200 is over capacity. Reduce the load on the pad.
BATT
BATTBATT
BATT
Low battery, the unit requires a new battery. It will shut off if this message
is ignored for too long.
Changing the Battery
Turn the power off. Slide the battery hatch down. Next, remove the battery from the
case and unsnap the used battery. Snap in the new battery and replace the battery in
the case. Replace the cover.