Advanced Entry Calibration (continued)
Step Operator Action Displayed Message Comment
11
P roceed a c c ording to your media
type:
Die-cut s to ck: strip the media
from the backing and then
reinsert it into the s ens or; adjus t
t he Sens or Eye Mar k over the
cent er of the b acking.
N ot ched st ock: adjust the
S ensor Eye M ar k over the c ent er
of the notc h.
Reflective stock: Adju st the
S ensor Eye M ar k over the c ent er
of the f acedown b lack ma rk.
Press the
Key to select
the setting and then record the
sens or reading in a ta b l e s imila r
t o the one s hown after S tep 12,
as a TOF Value.
Next, press the
FWD
Key to
in crement the G ai n Nu mber.
Repeat fo r each o f the G ain
Numbers (00-32).
!
HBJO!USBO!!!!!=zzz?!
+11!!!!!!!!)1!.!42*!
!
Or, for reflective media:
HBJO!SFGM!!!!!=zzz?!
+11!!!!!!!!)1!.!42*!
Wher e ‘ yyy’ is a numeric al va lue rep resenti ng the
cu rrent sens or reading: u sef ul in loc ati ng the b es t
s ens or posi ti on.
Note: Never posit ion the sensor over a per f or at ion
when r ecor ding a sensor reading.