User Manual
M-Class 73
Advanced Entry Calibration (continued)
Step Operator Action Displayed Message Comment
6
Press the
FWD
Key to scroll to
‘Advanced Entr y’.
!
TFOTPS!DBMJCSBUJPO!
BEWBODFE!FOUSZ!
!
You are entering Adva nced Entr y Ca libra ti on.
7
Press the
Ke y.
!
BEWBODFE!FOUSZ!
TFOTPS!MFWFMT!
!!
Press the
Key to a bort this pr ocedure.
8
Press the
FWD
Key.
!
BEWBODFE!FOUSZ!
TFOTPS!HBJO!
!!
You are b eginning t he Advanc ed E ntry C alibration.
9
Press the
Ke y.
P lace t he la bel u nder the Sens or
Eye Mark and lower the
print head assembly.
!
HBJO!USBO!!!!!=zzz?!
+11!!!!!!!!=1!.!42?!
!
-OR-
HBJO!SFGM!!!!!=zzz?!
+11!!!!!!!!)1!.!42*!
I f usin g prepri n ted medi a, en su re th e lab el area un d er
t he s ens or is free of prepri nted t ex t, graphic s or
borders.
10
Press the
Key to select
the setting (denoted by an ‘*’)
and then rec ord the sens or
reading ( the ‘yyy’ value) in a
t able s i mila r t o the one shown
after Step 12, as a L abel V alue.
Next, press the
FWD
Key to
in crement the G ai n Nu mber.
Repeat t h i s s tep fo r each o f the
Gain Numbers (00-32).
!
HBJO!USBO!!!!!=zzz?!
+11!!!!!!!!=1!.!42?!
!
-OR-
HBJO!SFGM!!!!!=zzz?!
+11!!!!!!!!)1!.!42*!
Wher e ‘ yyy’ is a numeric al va lue rep resenti ng the
cu rrent sens or reading: u sef ul in loc ati ng the b es t
s ens or posi ti on.
Note: Never posit ion the sensor over a per f or at ion
when r ecor ding a sensor reading.