Installation and Operation Manual Instruction Manual
25
8.0 Display Messages
The following table shows the messages that are displayed during operation of the IQ6200/6500.
Message Description
—Add XX Sample size is too small
All CLEAr Clearing all items in memory
C XX Number of items in memory
CH XX Checking part code
CLEAr Clearing one item in memory
dA - XX - XX - XX (IQ6500 only) Setting date and time
(printer) Comm on (IQ6500 only) (printer) Printer on
(printer) Comm off (IQ6500 only) (printer) Printer off
Err - (IQ6500 only) Error during data transfer
InSUFS Setting insufficient sample size
InVEnt CLEAr Clearing inventory data
Lo-Err Zero is out of range on the low side
L-YEAr (IQ6500 only) Setting Leap Year constant
P-no CLEAr Clearing part number
P-oFF (IQ6200 only) Setting “sleep” time for battery option
ProG. In programming mode
SEt 1 Setting setpoint 1
SEt 2 Setting setpoint 2
SPEC XX Setting Spec Data
t-C XX XX (IQ6500 only) Programming alpha/numeric part number
tArE CLEAr Clearing tare weight in memory
totAL XXXX Doing “+” “–” accumulating operation
through - C XX XX (IQ6500 only) Programming alpha/numeric part number
UnIt CLEAr Clearing unit weight in memory
UP-Err Zero is out of range on the high side
UEr - XXXX Software version number (only appears after scale is plugged into AC
power and turned on)