User Manual - Version 2.0
Counterpart User Manual - Serial Commands 67
REG.SNPSHOT Display or Scale weight source DISPLAY, SCALE
SD Set date MMDDYY, DDMMYY, YYMMDD, or YYDDMM. Enter six-digit
date using the year-month-day order specified for the
DATEFMT parameter, using only the last two digits of the year.
ST Set time hhmm (enter using 24-hour format)
TIMEFMT Time format 12HOUR, 24HOUR
TIMESEP Time separator COLON, COMMA
Command Description Values
GFMT.FMT Gross print format string See Section 7.0 on page 69 for information about demand print
format strings.
NFMT.FMT Net print format string
ACC.FMT Accumulator print format string
CFMT.FMT Count print format string
TOTAL.FMT Total print format string
SPFMT.FMT Setpoint print format string
HDRFMT1 Header 1 print format string
PALFMT.FMT Pallet print format string
HDRFMT2 Header 2 print format string
Table 6-7. PFORMT Serial Commands
Command Description Values
DIO#b Digital I/O function OFF, ZERO, NT/GRS, TARE, UNITS, PRINT,
CLEAR, CLRCN, GROSS, DSPACC, SAMPLE,
SFTKEY 1, SFTKEY 2, SFTKEY 3, SFTKEY 4,
OUTPUT
Digital inputs and outputs are specified by bit number
Table 6-8. DIG I/O Serial Commands
Command Description Value
GFMT.PORT Set the transmit port for each of these formats 2
NFMT.PORT
ACC.PORT
CFMT.PORT
TOTAL.PORT
PALFMT.PORT
SPFMT.PORT
Table 6-9. Select Port Serial Commands
Command Description Values
Table 6-6. FEATURE Serial Commands (Continued)