User Manual - Version 1.0 Owner's manual
Counterpart User Manual - For More Information 69
<M[G | N | T]> STR.GROSS
STR.NET
STR.TARE
Mode. Specifies gross, net, or tare weight for the current or
specified weight on the source scale.
<S> STR.MOTION
STR.RANGE
STR.OK
STR.INVALID
Status for the source scale. Default values and meanings for each
status:
STR.MOTIONMIn motion
STR.RANGEOOut of range
STR.OK<space>OK
STR.INVALIDIInvalid
<CW> — Status of over/under/accept. O=Over, U=Under, A=Accept.
<B [–]n,…> See descriptions below Bit fields. Comma-separated sequence of bit field specifiers. Must
be exactly 8 bits. Minus sign ([–]) inverts the bit.
B0 — Always 0
B1 — Always 1
B2 Configuration =1 if even parity
B3 Dynamic =1 if MODE=NET
B4 Dynamic =1 if COZ
B5 Dynamic =1 if standstill
B6 Dynamic =1 if gross negative
B7 Dynamic =1 if out of range
B8 Dynamic =1 if secondary/tertiary
B9 Dynamic =1 if tare in system
B10 Dynamic =1 if tare is keyed
B11 Dynamic =00 if MODE=GROSS
=01 if MODE=NET
=10 if MODE=TARE
=11 (not used)
B12 Dynamic =00 if UNITS=PRIMARY
=01 if UNITS=SECONDARY
=10 if UNITS=TERTIARY
=11 (not used)
B13 Configuration =00 (not used)
=01 if current DSPDIV=1
=10 if current DSPDIV=2
=11 if current DSPDIV=5
B14 Configuration =00 (not used)
=01 if primary DSPDIV=1
=10 if primary DSPDIV=2
=11 if primary DSPDIV=5
B15 Configuration =00 (not used)
=01 if secondary DSPDIV=1
=10 if secondary DSPDIV=2
=11 if secondary DSPDIV=5
B16 Configuration =00 (not used)
=01 if tertiary DSPDIV=1
=10 if tertiary DSPDIV=2
=11 if tertiary DSPDIV=5
Format Identifier Defined By Description
Table 9-3. Custom Stream Formatting