User Manual - Version 1.0 Owner's manual

Counterpart User Manual - Configuration 37
3.9 Display Menu
There are three display settings on the Counterpart.
Figure 3-13. DISPLAY Menu
Setting the display parameters from this top level menu is temporary - after a power cycle, the values will revert
to their previous values. Changes made to these parameters through the CONFIG menu are kept through a power
cycle.
LOOP TEST Performs a loop test on dig I/O cards.
DIO 1
DIO 2
DIO 3
DIO 4
STATUS Displays the status of each individual digital I/O port. If set as input, the display
shows input stats IN HI or IN LO. If set as output, pressing Enter toggles the
output between HI and LO. OUT HI or OUT LO.
OUT LO is active.
PORT1
PORT2
TEST Performs a loopback test on serial port 1 or 2. Connect jumper TX and RX
together on port 1 or port 2 before testing.
TEST Menu
Parameter Choices Description
Table 3-11. TEST Menu Parameters
CONTRAST
XXXXXXX
ID DISPLAYTESTSETUPAUDIT CALIBR
BRIGHT IMAGE
100
0-100%
50
0-100%
Negative
Positive