User Manual - Version 1.0 Owner's manual
Counterpart User Manual - Introduction 5
1.9 Indicator Operations
Basic Counterpart operations are summarized below.
Toggle Gross/Net
Press the GROSS/NET key to switch the display mode
from gross to net or from net to gross. If a tare value
has been entered or acquired, the net value is the gross
weight minus the tare. If no tare has been entered or
acquired, the display remains in gross mode.
Gross mode and Net mode is indicated by the
annunicator on the display.
Toggle Units
Press the UNITS TOGGLE key to switch between
primary, secondary, and tertiary units.
Zero Scale
1. While in gross mode, remove all weight from
the scale and wait for the standstill
annunicator (
).
2. Press the ZERO key. The zero annunicator is
displayed to indicate the scale is zeroed.
Acquire Tare
1. Place a container on the scale and wait for the
standstill annunicator (
).
2. Press the TARE key to acquire the tare weight
of the container.
3. The Net annunicator will be enabled.
Remove Stored Tare Value
1. Remove all weight from the scale and wait for
the standstill annunicator (
).
2. Press the TARE key. The display shifts to gross
weight and the Gross annuciator is displayed.
Keyed Tare
1. Key in the value of the container.
2. Press the TARE key.
3. The Net annunciator is displayed.
Print
Press the PRINT key to print either the Gross, Net,
Total or Count format.
The default format is a 2.25 x 4.5 inch label.
1. Wait for standstill annunciator ( ).
2. Press the PRINT key to send data to the serial
port.
If the standstill annunciator is not present, the PRINT
key command is executed if the scale comes out of
motion within three seconds.
Set Date and Time
1. If the softkey is enabled, push the softkey.
The current value is displayed.
2. To change, use the Up/Down arrows to
highlight the value to change.
3. Press the TARE key to save and exit.
Set Serial Scale (Scale 3)
1. Select Port 1 - Indust Scale
2. Match the baud rates. Upon doing this it
automatically becomes Scale 3.