User Manual Rev. E - Version 2.5 User guide

Appendix 93
B19 Configuration =000 if secondary DECPNT = 8888800
=001 if secondary DECPNT = 8888880
=010 if secondary DECPNT = 8888888
=011 if secondary DECPNT = 888888.8
=100 if secondary DECPNT = 88888.88
=101 if secondary DECPNT = 8888.888
=110 if secondary DECPNT = 888.8888
=111 if secondary DECPNT = 88.88888
B20 Configuration =000 if tertiary DECPNT = 8888800
=001 if tertiary DECPNT = 8888880
=010 if tertiary DECPNT = 8888888
=011 if tertiary DECPNT = 888888.8
=100 if tertiary DECPNT = 88888.88
=101 if tertiary DECPNT = 8888.888
=110 if tertiary DECPNT = 888.8888
=111 if tertiary DECPNT = 88.88888
<wspec [–]
[0] digit[[
.]digit]> Scale weight Weight for the source scale. wspec is defined as follows:
wspec Indicates whether the weight is the current displayed weight
(W, w), gross (G, g), net (N, n), or tare (T, t) weight. Upper-case
letters specify right-justified weights; lower-case are left-justified.
Optional /P, /S, or /T suffixes can be added
befor
e the ending
delimiter (>) to specify weight display in primary (/P), secondary (/
S), or tertiary (/T) units.
[–] Enter a minus sign (–) to include sign for negative va
lues.
[0] Enter a zero (0) to display leading zeroes.
digit[[.][.]digit]
The first digit indicates the field width in characters. Decimal point
only indica
te
s floating decimal; decimal point with following digit
indicates fixed decimal with n digits to the right of the decimal.
Two consecutive decimals send the decimal point even if it falls at
the end of the transmitted weight field.
<CR> Carriage return
<LF> Line feed
Format Identifier Defined By Description
Table 9-3. Custom Stream Formatting