User Manual Rev. E - Version 2.5 User guide
Serial Commands 75
SC.PRI.DSPDIV#n Primary units display divisions 1D, 2D, 5D
SC.PRI.UNITS#n Primary units lb, kg, g, oz, OFF
SC.ACCUM#n Accumulator enable ON, OFF
SC.WZERO#n Zero calibration
SC.WVAL#n Test weight value test_weight_value
SC.WSPAN#n Span calibration
SC.WLIN.F1–
SC.WLIN.F5#n
Actual raw count value for lin
earization points 1–5 0–16777215
SC.WLIN.V1
SC.WLIN.V5#n
Test weight value for linearization points 1–5 0.000001–9999999
SC.WLIN.C1–
SC.WLIN.C5#n
Calibrate linearization points 1–5
SC.LC.CD#n Deadload coefficient
SC.LC.CW#n Span coefficient
SC.LC.CZ#n Temporary zero
SC.REZERO#n Rezero
SC.SEC#n Secondary units lb, kg, g, oz, OFF
SC.TER#n Tertiary units lb, kg, g, oz, OFF
SC.N#n Report scale number being verified in Weigh Mode
Command Description Values
EDP.BAUD#p Port baud rate 1200, 2400, 4800, 9600, 19200, 288
00, 38400, 57600, 115200
EDP.BITS#p Port data bits/parity 8NONE, 7EVEN, 7ODD
EDP.STOPBITS#p Port stop bits 1, 2
EDP.PRNMSG#p Print message ON, OFF
EDP.ECHO#p Port echo ON, OFF
EDP.EOLDLY#p Port end-of-line delay 0–255 (0.1-sec
ond intervals)
EDP.HEADERS#p Port header ON, OFF
EDP.INPUT#p Port input PORT 1 - CMD, SCANNER, SCALE, IND SC
PORT 2 - CMD, SCANNER
PORT 3 - CMD, SCANNER, KEYBOARD
EDP.PORT Port reporting command. It responds to the port you a
re connected to.
EDP.RESPONSE#p Port response ON, OFF
EDP.SOURCE#p Port source 1, 2, 3
EDP.STREAM#p Port stream OFF, LFT, INDUST
EDP.TERMIN#p Port termination CR/LF, CR
Table 6-5. Serial Port Serial Commands
Command Description Values
Table 6-4. Scales Serial Commands