User Manual Rev. E - Version 2.5 User guide
Configuration 47
Gross, Net, Piecent, %REL
GROSS NET PIECECNT %REL
APPLIES TO GROSS, NET, PIECECNT, & %REL
SOURCE
LIST OF
SCALES
VALUE
number
TRIP
LOWER
HIGHER
OUTBAND
INBAND
BANDVAL
number
If TRIP=
INBAND or
OUTBAND
If TRIP=
HIGHER or
LOWER
HYSTER
number
PREACT
OFF
ON
LEARN
If PREACT=
ON or
LEARN
PREVAL
number
PRESTAB PCOUNTPREADJ
number
If KIND=
% RELSP
RELNUM
1-6
DIGOUT
NONE
1-4
SENSE
NORMAL
INVERT
ON
HIDE
OFF
ACCESS
PSHPRNT
OFF
ON
WAITSS
PSHTARE
OFF
ON
PSHACCM
OFF
ON
NQUIET
BATCH
OFF
ON
If PREACT
=
LEARN
Sub-menu
Figure 3-20. Gross, Net, Piecent, %REL Sub-menu
Parameters Choices Description
SP CFG SETPT 1
SETPT 2-6
Specifies the settings for GROSS, NET, PIECECNT, % RE
L, delay, waitss, counter and
inmotion used by setpoints 1 through 6.
BATCHING OFF
AUTO
MANUAL
Batching enable. Set to AUTO or MANUAL to allow a batch sequence to run. MANUAL
requires a Batch Start softkey before the batch sequence can run. AUTO allows batch
sequences to repeat continuously.
SP CFG subenu
SETPT1-6 OFF
GROSS
NET
PIECECNT
%REL
DELAY
WAITSS
COUNTER
INMOTION
Specifies the setpoint kind.
GROSS, NET, PIECECNT, and %REL setpoint kinds can
be used as e
ither batch or continuous
setpoints. DELAY, WAITSS, and COUNTER setpoint kinds can only be used in batch
sequences.
The INMOTION setpoint kind can only be used as a contin
uous setpoint.
Table 3-17. Scale Setpoint Menu Parameters