User Manual Rev. D - Version 2.4 Instruction Manual

48 Counterpart Counting Scale Indicator
Setpoint 1-6 submenu
OFF Value = number
GROSS
NET
PIECECNT
%REL
Value
Source
Trip
Bandval
Hyster
Preact
Preval
Preadj
Prestab
Pcount
Relnum
Batch
Pshaccm
Pshprint
Pshtare
Access
Digout
Sense
Display and edit the gross value
DELAY Value
Source
Pshaccm
Pshprint
Pshtare
Access
Digout
Sense
WAITSS Source
Pshaccm
Phsprint
Pshtare
Access
Digout
Sense
COUNTER Value
Access
Digout
INMOTION Source
Access
Digout
Sense
Off, Gross, Net, Peicecnt, %Rel, Delay, Waitss, Counter and Inmotion submenus
VALUE number
SOURCE List of available
scales
Specifiy the scale number used as the source for the setpoint.
TRIP Higher
Lower
Inband
Outband
Specifies whether the setpoint is satisfied when the weight is higher or lower than the setpoint
value, within a band established around the value, or outside of that band.
In a batch sequence with TRIP = HIGHER, the associated digital output is active until the
setpoint value is reached or exceeded; with TRIP = LOWER, the output is active until the
weight goes below the setpoint value.
BANDVAL number
HYSTER number Specifies a band around the setpoint value that must be exceeded before the setpoint, once
off, can trip on again.
Parameters Choices Description
Table 3-17. Scale Setpoint Menu Parameters