User Manual Rev. D - Version 2.4 Instruction Manual
40 Counterpart Counting Scale Indicator
Regulate Industry Menu
Only displayed if INDUST is selected
from the REGULAT parameter
REGULAT
INDUST
DISPLY
SCALE
SNPSHT
NO
YES
ZTARE
KTARE
YES
NO
CTARE
YES
NO
NTARE
NO
YES
MTARE
REMOVE
REPLAC
NOTHN
NO
YES
PRTMOT
NO
YES
PRTPT AGENCY
CALIB
SCALE
OVRBAS
NTEP
INDUST
NONE
OIML
CANADA
Figure 3-15. Regulate Industry Menu Layout
CODE Press CODE, enter ID number, press ENTER to recall stored item code. If item code does not exist, will
prompt “Item not found, Save as New ID?” Pressing YES will store in first available register. Alpha ON/OFF
sof
tkey appears to turn off Alpha to process numbers quicker when not using Alpha.
LOT Allows user to add lot number to sto
red item code on the fly (if enabled to do so)
PRINTPLT Allows user to print a pallet label
SWAPDSP Allows user to swap large display bet
ween weight, count, unit weight
RESET ID’S Reset or clear ID’s/codes.
IN Used to add, subtract count from inven
tory value (local or WeighVault)
OUT
CLRCN Sets consecutive number back to RESV
AL (beginning reset value)
QUANTITY Update quantity for IN/OUT
inventory database.
TOTAL+ Used with totalization mode or parts
reduction count mode to add or subtract items from total accumulated
count. CLRTTL will clear the totalized value.
TOTAL-
CLRTTL
UWUPDT Update stored unit weight or tare weight for currently loaded item code
TAREUPDT
SETPT Change setpoint value
BATSTRT Batch start
BATSTOP Batch stop
BATPAUSE Pause batch
BATRST
Reset batch
Parameters Descriptions
Table 3-13. Softkey Menu Parameters