Rice Lake Digital Chair Scale Model 550-10 Software Revision 11454 Operation Manual 130893 - Rev C
Contents 1.0 Introduction.................................................................................................................................. 1 2.0 3.0 Cautions and Warnings................................................................................................................ 2 Scale Assembly ........................................................................................................................... 3 3.1 Unpacking Your Scale . . . . . . . . . . . . . . . . . . . . .
Rice Lake continually offers web-based video training on a growing selection of product-related topics at no cost. Visit www.ricelake.com/webinars.
1.0 Introduction The Rice Lake 550 Digital Chair scale is efficiently designed to provide accurate, reliable and repeatable weight measurements and has features that enable a fast and convenient weighing process. The Rice Lake 550 Digital Chair scale features an ergonomic design, has two armrests that can be lifted separately and a foot rest that can be folded. Its four swivel casters can be locked in place. This manual can be viewed and downloaded from the Rice Lake Weighing Systems web site at www.
2.0 Safety With the Rice Lake 550 Digital Chair scale there are certain precautions that should be taken to prevent personal injury to the user and damage to your scale. 2.1 Safety Signals Safety Signal Definitions: WARNING Indicates a potentially hazardous situation that, if not avoided, may result in death or serious injury CAUTION Indicates a potentially hazardous situation that, if not avoided, may result in minor or moderate injury.
3.0 3.1 Scale Assembly Unpacking Your Scale Place the unopened box in an open area that has ample room for unpacking the scale. Parts contained in the shipping box include: • The chair scale • This manual • Box labeled Parts Inside • The Parts Inside box contains the following: • Serial communication cable • AA batteries (6) • 5 mm Allen key • M6 x 16 Allen screws (4) — (to attach seat to base) 3.
3. Remove top Styrofoam piece and remove the seat from the attached Styrofoam. Figure 3-2. Remove Seat From Packaging 4. Set the seat aside for later assembly. 5. Remove the side and the back handle Styrofoam pieces. Figure 3-3. Remove Side Styrofoam Pieces From Packaging Note The chair is heavy so use assistance in taking it out of the box and placing it on the floor, making sure it does not get dropped. Figure 3-4.
6. Lift chair off of Styrofoam packing material using assistance and place it on the floor. Figure 3-5. Lift Chair off of Styrofoam Bottom Packaging 7. Collect the Styrofoam pieces and place them back in the carton box. Chair Assembly Use the following steps to assemble the chair. 1. Use the Allen key provided in the “Parts Inside” box. 2. Release both of the screws holding the back handle frame (which is marked with circles in Figure 3-6). Remove screws to release the back handle frame.
3. Remove Styrofoam pieces from the main handle. Figure 3-7. Remove Styrofoam Packing Pieces from Main Handle 4. Pull out the back handle frame and rotate it so that the indicator will be facing up. Figure 3-8. Pull out Frame and Rotate 5. Insert the main handle into the frame and secure it with the screws. Tighten screws once frame has been rotated Figure 3-9.
6. Connect the load cell cable and indicator cable making sure to position the load cell cable on the grooves so that it doesn’t get damaged or pinched. Figure 3-10. Connect Load Cell Cable and Indicator Cable 7. Use the Allen key (provided) to release both screws holding the arm rest frame (marked with circles below). Figure 3-11. Loosen Screws Holding Arm Rest Frame 8. Rotate the arm rest until the arm rests are parallel to the seat base. 9. Tighten the screws to secure the arm rests in place.
11. Use level bubble to check for level and adjust feet as needed by adjusting bolts located on top of each caster wheel. Bubble level location Adjust bolt located above caster to adjust bubble level Figure 3-14. Bubble Indicates that the Scale is Level Note Ensure casters are in a locked position prior to having a patient sit down on the chair scale. Figure 3-15. Brake Location on Each Caster Wheel 12. Foot rest must be in the UP position prior to patient sitting down on the chair scale.
Inserting Batteries The Rice Lake 550 Digital Chair scale uses six (6) AA batteries which offers an average of 25 hours of continuous use from the batteries. The batteries come with the product. To install the batteries, 1. Open the battery chamber cover. 2. Insert batteries. Figure 3-17. Batteries in Battery Chamber 3. Close battery chamber cover. If an external power supply or USB power is connected, the battery flag on the display is turned off.
4.0 Scale Operation The Rice Lake 550 Digital Chair scale display has various front panel keys. They are shown below. Figure 4-1. Rice Lake 550 Digital Chair Scale Front Panel Display Keys Key Descriptions Table 4-1 describes each of the Rice Lake 550 Digital Chair scale’s key functions. Key Name Function On/Off Switches the scale on or off Print LB/KG Print - A long key press will send data out from the RS-232 and USB ports.
Key Name Function ENTER Used to accept height in BMI mode. Up/Down Arrows Used to adjust height input (0.5 in/0.5 cm) while in BMI mode. ENTER Table 4-1. Digital Chair Scale Key Functions Note The keys on the front panel display are very sensitive so only a gentle pushing motion is required to obtain results. CAUTION To prevent injury, do not exert unnecessary force on the arm rests. The scales have the capability of performing different operations beyond just calculating weight.
4.4 Toggle Tare Use the following steps to use the Toggle Tare function: 1. When the weight is set to 0.0, press the TARE key. 2. The default tare value is displayed (default is programmed to be 33.0 Lb/15.0 Kg), while the zero is flashing. 3. Use the UP/DOWN arrow keys to adjust the value. 4. Press ENTER to start the tare function and the NET annunciator will be turned on instead of the GROSS annunciator. 4.5 Using the Body Mass Index (BMI) Function Use the following steps in determining the BMI.
5.0 RS-232 Communication The scale comes with an RS-232 port which enables weight data to be transmitted to other equipment, such as a computer or printer. The RS-232 cable with DB-9 connector (PN 100719) is available from Rice Lake Weighing System. Figure 3-18 on page 9 shows where the RS-232 connection is. The RS-232 parameters are 9600 baud (selectable in the programming mode), 8 data bits, 1 stop bit, no parity and no handshaking.
Connecting software and downloads should be addressed by your IT department and can vary depending on what type of computer platform you’re using. Basic information on USB driver installation using Windows is described in the following steps and serves only as an example. The USB driver can be downloaded from the Rice Lake Weighing Systems website at the following location; http://www.ricelake.com/software.aspx Select Medical/Health Scales, Software and Get Downloads.
6. If you want to verify the installation, you can view the driver by looking at the device manager of your system. 7. To print a ticket using the USB driver, open the software driver (shown above) and the port assigned to that driver is shown. 8. Ensure that the USB cable is properly connected and the unit is on. 9. Another terminal type program (such as Hyperterminal) needs to be opened and connected through the USB driver to the indicator to be able to see the information being sent to the PC.
6.0 Troubleshooting and Testing Refer to the following instructions to check and correct any failure before contacting service personnel. Symptom Possible Cause Scale does not turn on Corrective Action Dead battery Connect the scale to a power source. Faulty electrical outlet Use a different electrical outlet. Bad power supply Replace optional adapter. External object is interfering with the scale Remove the interfering object from the scale. Display did not show 0.
8.
For More Information System Manuals • Rice Lake 550 Digital Chair Scale Technical Manual, PN 155191 Literature • 4-color 550-10 Series Digital Chair Scale 550-10 Series literature, PN 130955 Web Site • http://www.ricelakehealth.com Contact Information Hours of Operation Knowledgeable customer service representatives are available 6:30 a.m. - 6:30 p.m. Monday through Friday and 8 a.m. to 12 noon on Saturday.
Digital Chair Scale Limited Warranty Rice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installed by a Distributor or Original Equipment Manufacturer (OEM) will operate per written specifications as confirmed by the Distributor/OEM and accepted by RLWS. All systems and components are warranted against defects in materials and workmanship for two years. RLWS warrants that the equipment sold hereunder will conform to the current written specifications authorized by RLWS.
20 Digital Chair Scale Operation Manual
230 W. Coleman St. Rice Lake, WI 54868 USA U.S. 800-472-6703 Canada/Mexico 800-321-6703 International 715-234-9171 Europe +31 (0) 88 2349171 www.ricelake.com www.ricelake.mx www.ricelake.eu www.ricelake.co.in m.ricelake.