Installation guide

14
System Structure F Multiple Door Stations to Multiple Monitors via a network
This configuration is the most complex as you will need to change the IP address of each Door Station
and each Indoor Monitor. It will allow you to use up to 6 Indoor Monitors and 6 Door Stations all together.
You will also require a Cat5e network cable from each the Indoor Monitor and Door Station, to a network
switch or to your existing LAN.
You will have the option of using the default IP address range 10.22.5.x (and only changing the IP
Address of 1x Door Station) or using your own LAN IP address range (and changing the IP Address of all
units). However in this example we will be changing the IP address of all devices to match our own IP
range of 10.1.1.x
- Complex System Structure.
- IP Set Up Required for every device.
- This example uses your own IP Address range.
- This configuration can give you up to 6 Indoor Monitors and 6 Door Stations.
- Each Indoor Monitor and Door Station will require their own 12vDC power supply.
- Network switch required.