User guide

Page 37 of 57
To Make the Dial Patterns Visible Under Advanced Options
a) Complete the configuration of this TE110P, click Save, and make the
changes active (write down or remember the trunk group number).
b) Click the Call Routing tab then click Outbound Dial Map.
c) Click to edit one or more of the routes (for example, LOCAL).
d) In the Target field, edit to match the trunk group of the TE110P that you
configured.
e) Click Save to save your changes.
f) Modify each route to reflect the trunk group number of the TE100P if you
want that route’s dial strings to be available under the TE110P’s Advanced
Options list.
g) Click the Resources tab then click Phone Lines.
h) Click to edit your TE110P.
i) Click the Advanced Options checkbox and the dial strings will be
displayed for you to edit, as needed.
4. Check the Reverse Order check box to assign ports beginning with the first port
and working up.
Note: By default, Evolution PBX assigns ports beginning with the last port and
working down.
5. Click Save to save your changes.
6. Restart Evolution PBX via the Restart button in the Web Interface.
SangomaA101D,A102D,A104D
The Sangoma A101D, A102D, A104D are internal PCI cards that offer one, two, and four
T-1 digital interfaces respectively.
To Configure the Sangoma A101D, A102D and A104D
1. Follow the steps in the Installing Digital T-1 PCI Cards
section if your PCI card is
not already physically installed in your Evolution PBX server.
2. At the Evolution PBX server terminal screen type installsangoma to install
the Sangoma drivers (note that there are no spaces).
The server will automatically install the drivers and reboot the system.
3. Login to the Web interface and configure the card using the same information
provided for the Digium TE110P
but select T1/PRI-A101D, T1/PRI-A102D, or
T1/PRI-A104D rather than T1/PRI-TE110P in step 3.
RhinoR1T1,R2T1,R4T1
The Rhino R1T1, R2T1, or R4T1 are internal PCI cards that offer one, two, or four T-1
digital interfaces respectively.
To Configure Rhino R1T1, R2T1 and R4T1
1. At the Evolution PBX server terminal screen type installrhino to install the
Rhino drivers (note that there are no spaces).
The server will automatically install the drivers and reboot the system.
2. Login to the Web interface and configure the card using the same information
provided for the Digium TE110P
but select T1/PRI-R1T1, T1/PRI-R2T1, or T1/PRI-