User guide
Page 33 of 57
To Make the Dial Patterns Visible Under Advanced Options
a) Complete the configuration of this VoIP account, click Save, and make the
changes active (write down or remember the provider name).
b) Click the Call Routing tab then click Outbound Dial Map.
c) Click to edit one or more of the routes (for example, LOCAL).
d) In the Target field, edit to match the provider name of the VoIP account
that you configured.
e) Click Save to save your changes.
f) Modify each route to reflect the provider name of the VoIP account if you
want that route’s dial strings to be available under the VoIP account’s
Advanced Options list.
g) Click the Resources tab then click Phone Lines.
h) Click to edit your VoIP account.
i) Click the Advanced Options checkbox and the dial strings will be
displayed for you to edit, as needed.
4. Click the Calibrate Echo check box to force Evolution PBX to calibrate and
optimize the echo cancellation settings on the next boot of the server. This can
take approximately 3 minutes per line so make sure the reboot occurs in a
scheduled downtime window. Once calibrated, the settings will be remembered
between reboots. This only needs to be performed once. After the reboot the
checkbox will no longer be checked. Evolution PBX will use a set amount of echo
reduction based on the results of the echo calibration.
Note: Some PCI cards include hardware echo cancellation. If your card includes
hardware echo cancellation do not use echo calibration or echo training.
5. Click the Reverse Order check box to assign ports beginning with the first port
and working up.
Note: by default, Evolution PBX assigns ports beginning with the last port and
working down.
6. Click Save.
7. Restart Evolution PBX via the Restart button in the Web Interface.
DigiumTDM2400P
The Digium TDM2400P offers up to 24 analog ports. It has six slots for daughter
modules. Each daughter module provides four analog ports. Start with slot six (FXO port
24) and work down if you are installing fewer than 24 analog ports. For example, if you
have twelve FXO ports using three daughter modules the modules should be in slots 4
through six and you should use ports 12 through 24. The TDM2400P is a full length PCI
card so ensure that your server chassis has the space to accommodate it. The card uses
a RJ-21 connector (often referred to as an Amphinol connector). This is a 25-pair telco
connector that must be connected to a break-out panel or a punch-down block. Send an
Email to pbxsales@intuitivevoice.com
to purchase a cable and breakout box.
Configuration of the 2400P is similar to the TDM400P.
To Configure the Digium TDM2400P
1. Follow the steps in the Installing Analog PCI Cards
section if your PCI card is not
already physically installed in your Evolution PBX server.
2. Log in to the Web interface and configure the card using the same information
provided for the Digium TDM400P
but select Analog-TDM2400P rather than
Analog-TDM400P in step 3.