User Manual

Under-Counter Beverage Cooler
W31401000 E (Jan 2019) - 6 -
The room must be well ventilated and free from sources of ignition. It must not be located
in a position where refrigerant could gather in the event of a leak. If it is below ground
level then extra precautions may be necessary and an expert should be consulted. In
Australia and New Zealand, the provisions of AS1677:2 1998 and subsequent
amendments must be adhered to.
Please make sure the floor is level and even. If the cabinet is not level, hazards and
malfunctions may occur including, but not limited to, the condensate water not draining
away and the doors not functioning correctly. You may adjust the appliance using the
levelling feet, being careful not to pinch your fingers.
The appliance requires a minimum ventilation space at sides top and rear of 10 mm. The
front grille must be completely unobstructed. See Figure 2.
1.3 Connecting the cooler to the Power Supply
Please observe all of the warnings and procedures stated in section 1.1.
Please take care not to pinch or damage the power cord in any way. Please examine the
power cord for any splits, cuts or damage. If it is unsatisfactory then it must be replaced
according to the instructions stated in 1.1.
Plug in the cooler and tum on the power.
2.0 OPERATION
2.1 Operation of the appliance
The appliance is designed to run automatically. Defrosting is automatic. The condensate
water is evaporated automatically by the system.
Maintenance must be performed according to the procedures detailed in section 3 of
these instructions.
2.2 Adjustment of the temperature
The appliance has been factory set to the chill the bottles to optimum serving
temperature. To access the “SET POINT", simply press either of the UP or DOWN arrows
on the controller display panel. To adjust the SET POINT, continue to press either the UP
or DOWN arrows until the desired SET POINT is achieved. Then simply leave the
controller alone. The selected SET POINT will be locked in and the display will revert to
the current internal air temperature. Please note that in normal operation the SET
POINTdenotes the coldest temperature that the air will reach before switching off the
compressor. The air temperature will be allowed to rise by approximately 4 degrees
before the refrigeration is requested to activate again. The temperature of the stored
products may not have risen to the same extent as the air temperature.
1 Press temperature set point
Sub function: “up
Light switch 1 Press temperature set point
Sub function: “down