BEFORE YOU CALL FOR SERVICE…
Alarm (‘A’)
and Alert
(‘T’) Codes
Description Current Alarm Screen Display
A038
Gas relay #2 stuck closed. This could inadvertently
allow the gas valve to open. This will disable the
heater.
A038 Gas Relay 2 stuck closed. Call Tech Svc.
->If problem persists, please contact technical
support or service provider.
A039
This is a control board hardware fault and requires
control board replacement if persistent. This will
disable the heater.
A039 Flame sense cct fault. Call Tech Service
->If problem persists, please contact technical
support or service provider.
A040
This is a control board hardware fault and requires
control board replacement if persistent. This will
disable the heater.
A040 Controller RAM fault. Call Tech Service.
->If problem persists, please contact technical
support or service provider.
A041
This is a control board hardware fault and requires
control board replacement if persistent. This will
disable the heater.
A041 Controller ROM fault. Call Tech Service.
->If problem persists, please contact technical
support or service provider.
A042
This is a control board hardware fault and requires
control board replacement if persistent. This will
disable the heater.
A042 Controller EEPROM fault. Call Tech Svc.
->If problem persists, please contact technical
support or service provider.
A043
This is a control board hardware fault and requires
control board replacement if persistent. This will
disable the heater.
A043 IC Program execution fault. Call Tech Svc
->If problem persists, please contact technical
support or service provider.
A044
Input power frequency not 60 Hz. (outside allowable
deviation). This will disable the heater.
A044 Processor Clock/Line Frequency Disagree
->If problem persists, please contact technical
support or service provider.
A047
Resistance for the Flammable Leak Sensor has fallen
outside the expected operational range.
A047 Flammable Leak Sensor Failure
-> If problem persists, please contact technical support
or service provider.
A048
Resistance for the Flammable Leak Sensor has
exceeded a specified threshold indicating a flammable
vapor has been detected but the sensor is operating
within designed range.
A048 Flammable Leak Detected
-> If problem persists, please contact technical
support or service provider.
A101
This is a display board hardware fault and requires
control board replacement if persistent. This will
disable the heater.
A101 Configuration Data Restore Failure
->Initialization of the control system failed at
startup. Please contact technical support or service
provider.
A102 Set the internal clock time.
A102 Time Clock needs to be programmed
->Go to Settings, select time/date menu and set
the time and date.
A103
This is a display board hardware fault and requires
control board replacement if persistent. This will
disable the heater.
A103 Time Clock not advancing time properly
->contact your qualified service provider.