Instructions / Assembly

31
Alternative Vertical Vent Termination
Alternative vertical vent termination kits are commercially available. Please refer to the instruction sheet
packaged with the kit for complete installation instructions.
WARNING:
Under no circumstances should the exhaust pipe and the air intake pipe be connected together.
Support Hanger
Adjustable Roof Flashing
Support Clamp
Air Intake
Pipe
Exhaust Vent
Pipe
Minimum Clearance 18 inches above roof
Concentric Vent Termination
Upward slope 1/8” per foot
(10mm per meter) minimum
NOTE:
Ensure proper condensate management in all
vertical venting.
INSTALLATION
!