Instructions / Assembly

12
3/4" Check Valve
with 1/8" Hole
Pressure Gauge
Hot water line
Cold water line
3/4" Shut-Off
Valve (Typ.)
Gas Line
3/4" cold water
supply
Heat Trap
6” Min.
3/4" Shut-Off
Valve (Typ.)
2 Gallon Thermal Expansion
Tank (if required-not supplied
with water heater)
3/4" Shut-
Off Valve
(Typ.)
3/4" Tempered
domestic hot water
supply to house.
Minimum of 2'-0" developed length
of 3/4" type "L" copper from the
water heater connection.
Nominal 3/4" size mixing or
tempering valve (refer to warning
above). Follow mixing or tempering
valve manufacturer’s instructions
for installation of the valve.
Isolation valve in hot water
supply line to heating unit (not
supplied with water heater)
See diagrams above for proper
pipe application for vertical
or horizontal supply lines.
Temperature and Pressure Relief
Valve, tie to location approved by
local code
Temperature and pressure
relief valve discharge line
140°F (60°C)
120°F (49°C) to
130°F (54°C)
Water Heater drain pan installed
in accordance with the Local and
State Code
6” Air Gap
Isolation valve in
cold water return
line from heating
unit (not supplied
with water heater)
Drain valve
(not supplied
with water
heater)
Air vent
3/4" HWS & HWR
to Heating Coil.
Water Heater drain pan installed
in accordance with the Local
and State Code
Air Handler
T
FAN
ON
OFF
HEAT
COOL
To HVAC Unit.
Piping loop between
water heater and fan
coil shall be flow guard
gold CPVC or equal
Hot water to
space heater
Hot water coil
All bronze pump
Check valve internal
in pump
Air bleed valve
Water Sample Tap
TYPICAL PIPING DIAGRAM FOR COMBINATION POTABLE/SPACE HEATING INSTALLATION
Flow Control
Valve
INSTALLATION