Instructions / Assembly

26
GAS VALVE LED STATUS/PROBLEM PROBABLE CAUSE SOLUTION
Six-Four Flashes, three
second pause
System in Lockout/Flame
sense out of sequence
Gas Control (Thermostat's) valve
stuck open
Replace Gas Control (Thermostat)
Seven Flashes, three
second pause
System in Lockout/Pres-
ence of Flammable Va-
pors detected
Gasoline or other ammable
vapor(s) were detected
Faulty Flammable Vapor Sensor
Faulty Gas Control (Thermostat)
Ensure that no ammable vapor(s) are
present
Reset the Gas Control (Thermostat)
using "ON/OFF" switch located on the
front of the control
Replace Flammable Vapor Sensor
Replace Gas Control (Thermostat)
Eight-One Flash, three
second pause
System in Lockout/Flam-
mable Vapor Sensor fault
detected
Flammable vapor sensor values
out of range
Improper Flammable Vapor Sen-
sor wiring and/or connection(s)
Faulty Flammable Vapor Sensor
Inspect the Flammable Vapor Sensor
wiring and connection(s)
Replace Flammable Vapor Sensor
Replace Gas Control (Thermostat)
Eight-Two Flashes,
three second pause
System in Lockout/En-
ergy cutoff device fault
detected
Thermal well fault in Gas Control
(Thermostat)
Inspect the wiring connection(s) to the
thermal well
Replace the thermal well
Eight-Three Flashes,
three second pause
System in Lockout/Fault
in the electronics circuit
detected
Thermal well fault in Gas Control
(Thermostat)
Faulty Gas Control (Thermostat)
Replace thermal well
Replace Gas Control (Thermostat)
Eight-Four Flashes,
three second pause
System in Lockout/Fault
with the Gas Control
(Thermostat)
Gas Control (Thermostat) needs to
be reset
Gas Control (Thermostat) has been
damaged
Cycle the power to the Gas Control
(Thermostat)
Replace the Gas Control (Thermostat)
Gas Valve LED Codes cont.
CAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous
operation. VERIFY PROPER OPERATION AFTER SERVICING.
CAUTION: For your safety DO NOT attempt repair of gas piping, remote control, burners, vent connectors or other safety
devices. Refer repairs to qualified service personnel.