Instructions / Assembly
33
Demand Response (CTA-2045/JA13) Installations
A factory installed thermostatic mixing valve
conforming to ASSE 1017 was included in the
unit. The mixing valve has been set to 120°F
(49°C) outlet temperature with +/-5F tolerance.
For safety concern, a seal sticker is placed to
ensure customer safety. Adjusting thermistor
according to the dial to change the outlet water
temperature. Customize outlet temperature
might cause scalding, please proceed with
caution. Technician service is recommended
for setting accurate mixing outlet temperature
demanded by customer.
Hot Water Outlet
Factory Installed
HydroBoost Kit
(Default 120°F (49°C))
Cold Water Inlet