Specification

®
Fuel Type Description
Nominal
Gallon
Capacity
Rated
Gallon
Capacity
Model
Number
Recovery
in G.P.H.
90° F Rise
First Hour
Rating
(Gallons)
Tank
Height
A
Height to
Water Conn.
B
Diameter
C
Ship
Weight
(LBS.)
Uniform
Energy Factor
(UEF)
Electric Tall 55 55 XE55T06CG45U0 21 74 57 59-3/4 22-1/4 131 0.92
Electric Tall 50 45 XE50T06CG45U0 21 63 58-1/2 61-3/4 20-1/4 124 0.92
Electric Medium 50 45 XE50M06CG45U0 21 63 48 50-1/2 22-1/4 131 0.92
Electric Short 47 43 XE47S06CG45U0 21 54 32 34 26-1/4 152 0.92
Electric Tall 40 36 XE40T06CG45U0 21 55 60-3/4 63-5/8 18-1/4 108 0.92
Electric Medium 40 36 XE40M06CG45U0 21 55 48-3/8 50-1/4 20-1/4 109 0.93
Electric Medium 40 36 XE40M06CG38U0 21 55 48-3/8 50-1/4 20-1/4 109 0.93
Electric Short 38 35 XE38S06CG45U0 21 51 31-1/2 32-5/8 23 111 0.92
Electric Short 38 35 XE38S06CG38U0 17 51 31-1/2 32-5/8 23 111 0.92
Electric Short 36 33 XE36S06CG45U0 21 51 31-1/2 33 24-1/4 121 0.92
03/23 FORM NO. THD-PEDR6 Rev. 2
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
Rheem Water Heating 1115 Northmeadow Parkway, Suite 100
Roswell, Georgia 30076 www.rheem.com
with Demand Response High Efficiency Specifications
**Recovery = wattage/2.42 x temp. rise °F.
Example: 4500W = 21 GPH
2.42 x 90°
Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements.
• Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring, and 3800 or 4500 watt upper and lower heating elements.
* *Recovery calculations used are based on 4500 watt elements used in non-simultaneous operation.
LEED Point = 1
A
B
C
WATER CONNECTIONS ALL 3/4" N.P.T.
COLD WATER
CONNECTION
HOT WATER
CONNECTION
ANODE
ROD
8"
ECOPORT
(CTA-2045 PORT)