Instructions / Assembly

3
Time/Temperature Relationship in Scalds
Temperature Time To Produce a Serious Burn
120°F More than 5 minutes
125°F 1½ to 2 minutes
130°F About 30 seconds
135°F About 10 seconds
140°F Less than 5 seconds
145°F Less than 3 seconds
150°F About 1½ seconds
155°F About 1 second
Table courtesy of Shriners Burn Institute
The chart shown above may be used as a guide in
determining the proper water temperature for your
home.
!
DANGER: Households with small children,
disabled, or elderly persons may require a 120°F or
lower thermostat setting to prevent contact with
“HOT” water.
The temperature of the water in the heater is
regulated by the adjustable surface mounted
thermostat(s) located behind the jacket access
panel(s). Dual element heaters have two thermostats.
To comply with safety regulations the thermostat(s)
were set at 120°F before the water heater was
shipped from the factory.
The illustration at the left
shows the temperature
adjustment dial used
for setting the water
temperature.
Refer to the Operating
Instructions in this
manual for detailed
instructions in how to
adjust the thermostat(s).
!
DANGER: Hotter water increases the potential for
Hot Water SCALDS.
DANGER
!
HOT
Water temperature over 125° F can
cause severe burns instantly or
death from scalds.
Children, disabled and elderly are
at highest risk of being scalded.
See instruction manual before
setting temperature at water
heater.
Feel water before bathing or
showering.
Temperature limiting valves are
available, see manual.
BURN
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
R
E
S
E
T
R
E
S
E
T
TURN OFF
POWER
BEFORE
SERVICING
90°F150°F
125°F
(66°C)
(52°C)
(32°C)
Reset button
Thermostat
protective
cover
Thermostat dial
pointer
DANGER!
WATER TEMPERATURE SETTING
Safety and energy conservation are factors to be considered when selecting the
water temperature setting of water heaters thermostat. Water temperatures
above 125°F can cause severe burns or death from scalding. Be sure to read and
follow the warnings outlined on the label pictured below. This label is also located
on the water heater near the thermostat access panel.
NOTICE: Mixing valves are recommended for
reducing point of use water temperature by mixing
hot and cold water in branch water lines. It is
recommended that a mixing valve complying with
the Standard for Temperature Actuated Mixing
Valves for Hot Water Distribution Systems, ASSE
1017 be installed. See page 13 for more details and
contact a licensed plumber or the local plumbing
authority for further information.