Insulation blankets, available to the
general public, for external use on electric
water heaters are not necessary. The
purpose of an insulation blanket is to
reduce the standby heat loss encountered
with storage tank heaters. This water
heater meets or exceeds the National
Appliance Energy Conservation Act
standards with respect to insulation and
standby loss requirements making an
insulation blanket unnecessary.
The manufacturer’s warranty does not
cover any damage or defect caused by
installation, attachment or use of
any type of energy saving or other
unapproved devices (other than those
authorized by the manufacturer) into, onto
or in conjunction with the water heater.
The use of unauthorized energy saving
devices may shorten the life of the water
heater and may endanger life and property.
The manufacturer disclaims any
responsibility for such loss or injury
resulting from the use of such
unauthorized devices.
!
CAUTION: If local codes require the
application of an external insulation
blanket to this water heater, pay careful
attention to the following so as not to
restrict the proper function and
operation of the water heater:
DO NOT cover the operating or
warning labels attached to the water
heater or attempt to relocate them on
the exterior of insulation blanket.
DO NOT apply insulation to the top of
the water heater. This could interfere
with the safe operation of the electrical
junction box.
DO NOT cover the jacket access
panel(s) to the thermostat(s) and heating
element(s), or pressure and temperature
relief valve.
Inspect the insulation blanket frequently.
!
WARNING: If local
codes require external
application of insulation
blanket kits the
manufacturer’s instructions
included with the kit must
be carefully followed.
Insulation Blankets
3 Phase
Wiring
Total Water
Heater Wattage
Recommended Over Current Protection
(Fuse or circuit breaker amperage rating)
Copper Wire Size AWG Based on NE.C.
Table 310-16 (75°C)
208V 240V 277V 480V 208V 240V 277V 480V
3,000 20 20 15 15 12 12 14 14
4,000 25 25 20 15 10 10 12 14
4,500 30 25 25 15 10 10 10 14
5,000 30 30 25 15 10 10 10 14
5,500 35 30 25 15 8 10 10 14
6,000 40 35 30 20 8 8 10 12
8,000 50 45 40 25 8 8 8 10
9,000 - 50 45 25 - 8 8 10
10,000 - - 50 30 - - 8 10
11,000 - - 50 30 - - 8 10
12,000 - - - 35 - - - 8